Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

DEVELOPMENT OF NEW TWO-DOSIMETER ALGORITHM FOR EFFECTIVE DOSE IN ICRP PUBLICATION 103

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorCho, Sungkoo-
dc.contributor.authorJeong, Jong Hwi-
dc.contributor.authorBolch, Wesley E.-
dc.contributor.authorReece, Warren D.-
dc.contributor.authorPoston, John W., Sr.-
dc.date.accessioned2022-07-16T20:44:59Z-
dc.date.available2022-07-16T20:44:59Z-
dc.date.created2021-05-12-
dc.date.issued2011-05-
dc.identifier.issn0017-9078-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168512-
dc.description.abstractThe two-dosimeter method, which employs one dosimeter on the chest and the other on the back, determines the effective dose with sufficient accuracy for complex or unknown irradiation geometries. The two-dosimeter method, with a suitable algorithm, neither significantly overestimates (in most cases) nor seriously underestimates the effective dose, not even for extreme exposure geometries. Recently, however, the definition of the effective dose itself was changed in ICRP Publication 103; that is, the organ and tissue configuration employed in calculations of effective dose, along with the related tissue weighting factors, was significantly modified. In the present study, therefore, a two-dosimeter algorithm was developed for the new ICRP 103 definition of effective dose. To that end, first, effective doses and personal dosimeter responses were calculated using the ICRP reference phantoms and the MCNPX code for many incident beam directions. Next, a systematic analysis of the calculated values was performed to determine an optimal algorithm. Finally, the developed algorithm was tested by applying it to beam irradiation geometries specifically selected as extreme exposure geometries, and the results were compared with those for the previous algorithm that had been developed for the effective dose given in ICRP Publication 60. Health Phys. 100( 5): 462-467-
dc.language영어-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.titleDEVELOPMENT OF NEW TWO-DOSIMETER ALGORITHM FOR EFFECTIVE DOSE IN ICRP PUBLICATION 103-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1097/HP.0b013e3181f186c9-
dc.identifier.scopusid2-s2.0-79955005116-
dc.identifier.wosid000288968600002-
dc.identifier.bibliographicCitationHEALTH PHYSICS, v.100, no.5, pp.462 - 467-
dc.relation.isPartOfHEALTH PHYSICS-
dc.citation.titleHEALTH PHYSICS-
dc.citation.volume100-
dc.citation.number5-
dc.citation.startPage462-
dc.citation.endPage467-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusPHOTON EXPOSURES-
dc.subject.keywordPlusEQUIVALENT-
dc.subject.keywordPlusDOSIMETERS-
dc.subject.keywordPlusPOINT-
dc.subject.keywordAuthoralgorithm-
dc.subject.keywordAuthordose assessment-
dc.subject.keywordAuthoreffective dose-
dc.subject.keywordAuthorMonte Carlo-
dc.identifier.urlhttps://journals.lww.com/health-physics/Fulltext/2011/05000/DEVELOPMENT_OF_NEW_TWO_DOSIMETER_ALGORITHM_FOR.2.aspx-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE