Cited 0 time in
Experimental performance of double-scattering Compton camera with anthropomorphic phantom
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Seo, Hee | - |
| dc.contributor.author | Park, Jahng Hyon | - |
| dc.contributor.author | Ushakov, Anatoly | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Kim, Jang Kyoung | - |
| dc.contributor.author | Lee, Ju Hahn | - |
| dc.contributor.author | Lee, Chun Sik | - |
| dc.contributor.author | Lee, Jae Sung | - |
| dc.date.accessioned | 2022-07-16T22:19:14Z | - |
| dc.date.available | 2022-07-16T22:19:14Z | - |
| dc.date.issued | 2011-01 | - |
| dc.identifier.issn | 1748-0221 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/169255 | - |
| dc.description.abstract | In proton therapy, it is important to very accurately determine the range of the proton beam. Recently it was found that this range can be determined from the distribution of the prompt gammas generated along the beam's passage. The Compton imaging technique can be considered to be a promising candidate for accurate determination of prompt gamma distributions, in that it produces a better image for higher-energy gammas when compared with conventional mechanical-collimation- type imagers. In the present study, the Compton imaging technique was evaluated by experimentally obtaining Compton images of relatively high-energy gamma sources positioned in an anthropomorphic phantom. Preparatory to that, two point-like gamma sources, Cs-137 (662 keV) and Na-22 (1275 keV), were placed in the brain region of the phantom at different depths and imaged using a double-scattering Compton camera. The Compton camera, recently developed as a prototype system, consists of two position-sensitive semiconductor detectors as scatterer detectors and a scintillation detector as an absorber detector. The evaluated imaging and angular resolutions for the source energies of 662 and 1275 keV were 13.7 mm and 5.9 degrees FWHM and 11.4 mm and 3.8 degrees FWHM, respectively. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Physics | - |
| dc.title | Experimental performance of double-scattering Compton camera with anthropomorphic phantom | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1088/1748-0221/6/01/C01024 | - |
| dc.identifier.scopusid | 2-s2.0-79952659865 | - |
| dc.identifier.wosid | 000291345600029 | - |
| dc.identifier.bibliographicCitation | Journal of Instrumentation, v.6, pp 1 - 7 | - |
| dc.citation.title | Journal of Instrumentation | - |
| dc.citation.volume | 6 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 7 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | RECONSTRUCTION | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.subject.keywordAuthor | Compton imaging | - |
| dc.subject.keywordAuthor | Instrumentation for hadron therapy | - |
| dc.subject.keywordAuthor | Instrumentation for heavyion therapy | - |
| dc.identifier.url | https://iopscience.iop.org/article/10.1088/1748-0221/6/01/C01024 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
