Cited 0 time in
무지 외반증의 중증도에 대한 전산화 영상 계측
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 강창남 | - |
| dc.contributor.author | 최경진 | - |
| dc.contributor.author | 이두연 | - |
| dc.contributor.author | 김상덕 | - |
| dc.contributor.author | 성일훈 | - |
| dc.date.accessioned | 2022-10-07T09:35:26Z | - |
| dc.date.available | 2022-10-07T09:35:26Z | - |
| dc.date.issued | 2009-06 | - |
| dc.identifier.issn | 1738-3757 | - |
| dc.identifier.issn | 2288-8551 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/171673 | - |
| dc.description.abstract | Purpose: To study the reliability of intra- and interobserver reliability in angular measurement of hallux valgus deformity by assessing hallux valgus angle (HVA) and the 1st to 2nd intermetatarsal angle (1-2 IMA) through using computerized system. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. With the standing anteroposterior view of foot, the HVA and 1-2 IMA were calculated by computerized measurement system of Infinity cooperation, called π-view, with its software tools. Using the statistical software program, SPSS (version 12th), we interpreted the results which were measured by two independent observers. Results: In the intraobserver measurement, the HVA of observer A showed reliability (32.5°±6.9 and 33.1°±6.8)(p<0.05). 1-2 IMA in observer A was not regarded as reliable (16.9°±2.8 and 17.1°±2.8)(p>0.05). In the results of observer B, HVAs were measured as 35.7°±7.6 and 36.2°±7.7, and were not reliable (p>0.05). 1-2 IMA in observer B was not reliable as well (17.0°±0.8 and 20.8°±1.5)(p>0.05). In the interobservers’ measurements, the first and the second results of HVA were 3.2°±3.6 and 3.1°±3.1, reliable within the 95% confidence interval (p<0.05). 1-2 IMAs were 0.1°±1.9 and 3.73°±1.3, which were not reliable (p>0.05). Conclusion: In the angular measurement of the hallux valgus by computerized system, the HVA and 1-2 IMA showed less error range in the interobserver’s results, compared with the previous studies about the manual measurement. However, our results failed to show the statistical reliability of intra- and interobserver’s measuring. Therefore, even the computerized angular measurements in the severity of hallux valgus require development of the measuring methods and software tools. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한족부족관절학회 | - |
| dc.title | 무지 외반증의 중증도에 대한 전산화 영상 계측 | - |
| dc.title.alternative | The Computerized Measurement for the Radiological Severity of Hallux Valgus | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 대한족부족관절학회지, v.13, no.1, pp 1 - 6 | - |
| dc.citation.title | 대한족부족관절학회지 | - |
| dc.citation.volume | 13 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 6 | - |
| dc.identifier.kciid | ART001347987 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kciCandi | - |
| dc.subject.keywordAuthor | Hallux valgus | - |
| dc.subject.keywordAuthor | Hallux valgus angle | - |
| dc.subject.keywordAuthor | Intermetatarsal angle | - |
| dc.subject.keywordAuthor | Computerized measurement | - |
| dc.identifier.url | http://www.earticle.net/Public/View/1/657986 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.