Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

무지 외반증의 중증도에 대한 전산화 영상 계측

Full metadata record
DC Field Value Language
dc.contributor.author강창남-
dc.contributor.author최경진-
dc.contributor.author이두연-
dc.contributor.author김상덕-
dc.contributor.author성일훈-
dc.date.accessioned2022-10-07T09:35:26Z-
dc.date.available2022-10-07T09:35:26Z-
dc.date.created2022-09-19-
dc.date.issued2009-06-
dc.identifier.issn1738-3757-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/171673-
dc.description.abstractPurpose: To study the reliability of intra- and interobserver reliability in angular measurement of hallux valgus deformity by assessing hallux valgus angle (HVA) and the 1st to 2nd intermetatarsal angle (1-2 IMA) through using computerized system. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. With the standing anteroposterior view of foot, the HVA and 1-2 IMA were calculated by computerized measurement system of Infinity cooperation, called π-view, with its software tools. Using the statistical software program, SPSS (version 12th), we interpreted the results which were measured by two independent observers. Results: In the intraobserver measurement, the HVA of observer A showed reliability (32.5°±6.9 and 33.1°±6.8)(p<0.05). 1-2 IMA in observer A was not regarded as reliable (16.9°±2.8 and 17.1°±2.8)(p>0.05). In the results of observer B, HVAs were measured as 35.7°±7.6 and 36.2°±7.7, and were not reliable (p>0.05). 1-2 IMA in observer B was not reliable as well (17.0°±0.8 and 20.8°±1.5)(p>0.05). In the interobservers’ measurements, the first and the second results of HVA were 3.2°±3.6 and 3.1°±3.1, reliable within the 95% confidence interval (p<0.05). 1-2 IMAs were 0.1°±1.9 and 3.73°±1.3, which were not reliable (p>0.05). Conclusion: In the angular measurement of the hallux valgus by computerized system, the HVA and 1-2 IMA showed less error range in the interobserver’s results, compared with the previous studies about the manual measurement. However, our results failed to show the statistical reliability of intra- and interobserver’s measuring. Therefore, even the computerized angular measurements in the severity of hallux valgus require development of the measuring methods and software tools.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한족부족관절학회-
dc.title무지 외반증의 중증도에 대한 전산화 영상 계측-
dc.title.alternativeThe Computerized Measurement for the Radiological Severity of Hallux Valgus-
dc.typeArticle-
dc.contributor.affiliatedAuthor강창남-
dc.contributor.affiliatedAuthor성일훈-
dc.identifier.bibliographicCitation대한족부족관절학회지, v.13, no.1, pp.1 - 6-
dc.relation.isPartOf대한족부족관절학회지-
dc.citation.title대한족부족관절학회지-
dc.citation.volume13-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage6-
dc.type.rimsART-
dc.identifier.kciidART001347987-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorHallux valgus-
dc.subject.keywordAuthorHallux valgus angle-
dc.subject.keywordAuthorIntermetatarsal angle-
dc.subject.keywordAuthorComputerized measurement-
dc.identifier.urlhttp://www.earticle.net/Public/View/1/657986-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 정형외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Chang Nam photo

Kang, Chang Nam
COLLEGE OF MEDICINE (DEPARTMENT OF ORTHOPEDIC SURGERY)
Read more

Altmetrics

Total Views & Downloads

BROWSE