Cited 0 time in
Simple and reliable Raman measurement of an etchant solution directly through Teflon tubing
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Donghyuk | - |
| dc.contributor.author | Chung, Hoeil | - |
| dc.contributor.author | Kim, Nakjoong | - |
| dc.date.accessioned | 2022-10-07T11:30:20Z | - |
| dc.date.available | 2022-10-07T11:30:20Z | - |
| dc.date.issued | 2007-04 | - |
| dc.identifier.issn | 0003-7028 | - |
| dc.identifier.issn | 1943-3530 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172321 | - |
| dc.description.abstract | A semiconductor etchant solution was analyzed using wide area illumination (WAI) through Teflon tubing. A diluted sulfuric acid/hydrogen peroxide (DSP) solution, composed of hydrogen peroxide and sulfuric acid in water, was selected and Raman spectra were collected using the WAI scheme. The concentration of each component was determined by generating random numbers to minimize correlations among them. Principal component regression was utilized to determine H2O2 and H2SO4 concentrations. The calibration models were developed using the calibration set, and its prediction performance was evaluated by predicting spectra in the validation set. Raman bands of H2SO4 were observed at 1050, 980, and 895 cm-1. Results show that these bands correspond to the vibration of acid sulfate, and the intensities of these peaks increases with respect to increased concentration. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Society for Applied Spectroscopy | - |
| dc.title | Simple and reliable Raman measurement of an etchant solution directly through Teflon tubing | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1366/000370207780466235 | - |
| dc.identifier.scopusid | 2-s2.0-34247264462 | - |
| dc.identifier.wosid | 000245537200014 | - |
| dc.identifier.bibliographicCitation | Applied Spectroscopy, v.61, no.4, pp 447 - 450 | - |
| dc.citation.title | Applied Spectroscopy | - |
| dc.citation.volume | 61 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 447 | - |
| dc.citation.endPage | 450 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalResearchArea | Spectroscopy | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Spectroscopy | - |
| dc.subject.keywordPlus | NEAR-INFRARED SPECTROSCOPY | - |
| dc.subject.keywordPlus | HYDROGEN-PEROXIDE | - |
| dc.subject.keywordPlus | ETCHING SOLUTION | - |
| dc.subject.keywordAuthor | etchant solution | - |
| dc.subject.keywordAuthor | synchronous standard | - |
| dc.subject.keywordAuthor | Teflon tube | - |
| dc.subject.keywordAuthor | Raman spectroscopy | - |
| dc.identifier.url | https://journals.sagepub.com/doi/10.1366/000370207780466235 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
