지반특성과 지진지역에 따른 보통모멘트골조의 내진성능평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 한상환 | - |
dc.contributor.author | 김인정 | - |
dc.date.accessioned | 2022-10-07T11:53:23Z | - |
dc.date.available | 2022-10-07T11:53:23Z | - |
dc.date.created | 2022-09-19 | - |
dc.date.issued | 2006-07 | - |
dc.identifier.issn | 1226-9107 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172438 | - |
dc.description.abstract | The purpose of this study is to evaluate the seismic performance of Ordinary Moment Resisting Concrete Frames(OMRCF) which is designed and detailed in compliance with ACI 318(1999). Based on the test results of 3-story OMRCF, this study adopts capacity spectrum method to evaluate the seismic performance of the frame. The capacity curve was obtained from the experimental results of the 3-story OMRCF and the demand curve was established using the earthquake ground motions recorded at various stations with different soil conditions. Evaluation results show that the 3-story OMRCF can resist seismic loads of all seismic zones, 1, 2A, 2B, 3, and 4 with soil type SA and SB. For soil type SC, the specimen is satisfactory in seismic zone 1, 2A, 2B, and 3. For soil type SD, the OMRCF was only valid for seismic zone 1 and 2A. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한건축학회 | - |
dc.title | 지반특성과 지진지역에 따른 보통모멘트골조의 내진성능평가 | - |
dc.title.alternative | Seismic Performance Evaluation of Three-story OMRCF according to Different Seismic Zones and Soil Types | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 한상환 | - |
dc.identifier.bibliographicCitation | 대한건축학회논문집 구조계, v.22, no.7, pp.19 - 25 | - |
dc.relation.isPartOf | 대한건축학회논문집 구조계 | - |
dc.citation.title | 대한건축학회논문집 구조계 | - |
dc.citation.volume | 22 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 19 | - |
dc.citation.endPage | 25 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001019087 | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Concrete Structures | - |
dc.subject.keywordAuthor | Performance Evaluation | - |
dc.subject.keywordAuthor | Base Shear | - |
dc.subject.keywordAuthor | Capacity Spectrum Method | - |
dc.subject.keywordAuthor | 콘크리트 구조 | - |
dc.subject.keywordAuthor | 이력 평가 | - |
dc.subject.keywordAuthor | 밑면 전단력 | - |
dc.subject.keywordAuthor | 능력스펙트럼법 | - |
dc.subject.keywordAuthor | Concrete Structures | - |
dc.subject.keywordAuthor | Performance Evaluation | - |
dc.subject.keywordAuthor | Base Shear | - |
dc.subject.keywordAuthor | Capacity Spectrum Method | - |
dc.identifier.url | https://www.dbpia.co.kr/pdf/pdfView.do?nodeId=NODE02305232&googleIPSandBox=false&mark=0&useDate=&ipRange=false&accessgl=Y&language=ko_KR&hasTopBanner=true | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.