Cited 0 time in
Fetal heartrate tracking system based on intensity of Doppler signal
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jo, Hyeong Geun | - |
| dc.contributor.author | Park, Beom Hoon | - |
| dc.contributor.author | Jo, Jung Ki | - |
| dc.contributor.author | Hoh, Jeong-Kyu | - |
| dc.contributor.author | Park, Kwan Kyu | - |
| dc.date.accessioned | 2022-10-25T06:57:04Z | - |
| dc.date.available | 2022-10-25T06:57:04Z | - |
| dc.date.created | 2022-10-06 | - |
| dc.date.issued | 2022-10 | - |
| dc.identifier.issn | 0263-2241 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172528 | - |
| dc.description.abstract | Doppler-detected fetal heart rate (FHR) tracking is the primary testing method for assessing fetal well-being during antepartum care. However, owing to fetal movements or maternal position variations, the transducer on the abdomen can be displaced, changing the fetal heart location (FHL) and resulting in frequent signal losses and uninterpretable results. In this study, we present FHR monitoring system for continuously maintaining FHR measurements without specifying the location of the Doppler ultrasound transducer. An algorithm is developed to track the FHL based on the intensity of the received Doppler signal. The performance is evaluated by conducting underwater experiments using an object with repeated movements. The tracking error is 7.93° on the X-axis and 1.42° on the Y-axis. Even with those tracking errors, the FHR is continuously recorded. This system can be used to obtain heart rate records without manipulating the position of the transducer and losing the signal. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | ELSEVIER SCI LTD | - |
| dc.title | Fetal heartrate tracking system based on intensity of Doppler signal | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Jo, Jung Ki | - |
| dc.contributor.affiliatedAuthor | Park, Kwan Kyu | - |
| dc.identifier.doi | 10.1016/j.measurement.2022.111896 | - |
| dc.identifier.scopusid | 2-s2.0-85138108905 | - |
| dc.identifier.wosid | 000860298500004 | - |
| dc.identifier.bibliographicCitation | MEASUREMENT, v.202, pp.1 - 10 | - |
| dc.relation.isPartOf | MEASUREMENT | - |
| dc.citation.title | MEASUREMENT | - |
| dc.citation.volume | 202 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 10 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Article | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | Degrees of freedom (mechanics) | - |
| dc.subject.keywordPlus | Heart | - |
| dc.subject.keywordPlus | Tracking (position) | - |
| dc.subject.keywordPlus | Ultrasonic transducers | - |
| dc.subject.keywordPlus | Well testing | - |
| dc.subject.keywordPlus | Location | - |
| dc.subject.keywordPlus | Autocorrelation function | - |
| dc.subject.keywordPlus | Autocorrelation functions | - |
| dc.subject.keywordPlus | Doppler ultrasound | - |
| dc.subject.keywordPlus | Fetal heart | - |
| dc.subject.keywordPlus | Fetal heart location | - |
| dc.subject.keywordPlus | Fetal heart rate | - |
| dc.subject.keywordPlus | Foetal heart rates | - |
| dc.subject.keywordPlus | Heart-rate | - |
| dc.subject.keywordPlus | Two-degree of freedom | - |
| dc.subject.keywordPlus | Two-degree-of-freedom | - |
| dc.subject.keywordAuthor | Doppler ultrasound | - |
| dc.subject.keywordAuthor | Fetal heart rate (FHR) | - |
| dc.subject.keywordAuthor | Fetal heart location (FHL) | - |
| dc.subject.keywordAuthor | Autocorrelation function (ACF) | - |
| dc.subject.keywordAuthor | Two-degree of freedom (DOF) | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0263224122010922?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.