Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Incorporation of micro-CT-based detailed bone models into ICRP adult mesh-type reference computational phantoms

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Bangho-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorBolch, Wesley E.-
dc.contributor.authorHan, Haegin-
dc.contributor.authorNguyen, Thang Tat-
dc.contributor.authorMoon, Sungho-
dc.contributor.authorSon, Gahee-
dc.contributor.authorKim, Suhyeon-
dc.contributor.authorKim, Hyeonil-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2022-10-25T07:39:26Z-
dc.date.available2022-10-25T07:39:26Z-
dc.date.created2022-10-06-
dc.date.issued2022-09-
dc.identifier.issn0031-9155-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172555-
dc.description.abstractObjective. The red bone marrow (RBM) and bone endosteum (BE), which are required for effective dose calculation, are macroscopically modeled in the reference phantoms of the international commission on radiological protection (ICRP) due to their microscopic and complex histology. In the present study, the detailed bone models were developed to simplify the dose calculation process for skeletal dosimetry. Approach. The detailed bone models were developed based on the bone models developed at the University of Florida. A new method was used to update the definition of BE region by storing the BE location indices using virtual sub-voxels. The detailed bone models were then installed in the spongiosa regions of the ICRP mesh-type reference computational phantoms (MRCPs) via the parallel geometry feature of the Geant4 code. Main results. Comparing the results between the detailed-bone-installed MRCPs and the original MRCPs with the absorbed dose to spongiosa and fluence-to-dose response function (DRF)-based methods, the DRF-based method showed much smaller but still significant differences. Compared with the values given in ICRP Publications 116 and 133, the differences were very large (i.e. several orders of magnitudes), due mainly to the anatomical improvement of the skeletal system in the MRCPs; that is, spongiosa and medullary cavity are fully enclosed by cortical bone in the MRCPs but not in the ICRP-110 phantoms. Significance. The detailed bone models enable the direct calculation of the absorbed doses to the RBM and BE, simplifying the dose calculation process and potentially improving the consistency and accuracy of skeletal dosimetry.-
dc.language영어-
dc.language.isoen-
dc.publisherIOP Publishing Ltd-
dc.titleIncorporation of micro-CT-based detailed bone models into ICRP adult mesh-type reference computational phantoms-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1088/1361-6560/ac8af4-
dc.identifier.scopusid2-s2.0-85138446960-
dc.identifier.wosid000853751200001-
dc.identifier.bibliographicCitationPHYSICS IN MEDICINE AND BIOLOGY, v.67, no.18, pp.1 - 16-
dc.relation.isPartOfPHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.titlePHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.volume67-
dc.citation.number18-
dc.citation.startPage1-
dc.citation.endPage16-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusSKELETAL DOSIMETRY MODEL-
dc.subject.keywordPlusABSORBED FRACTIONS-
dc.subject.keywordPlusRESPONSE FUNCTIONS-
dc.subject.keywordPlusTRANSPORT-
dc.subject.keywordPlusPARTICLE-
dc.subject.keywordPlusTISSUES-
dc.subject.keywordAuthorICRP reference computational phantom-
dc.subject.keywordAuthormicro-CT-based detailed bone model-
dc.subject.keywordAuthorred bone marrow-
dc.subject.keywordAuthorbone endosteum-
dc.subject.keywordAuthorMonte Carlo dose calculation-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/1361-6560/ac8af4-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE