Geometric-phase intraocular lenses with multifocality
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Seungmin | - |
dc.contributor.author | Park, Gayeon | - |
dc.contributor.author | Kim, Seonho | - |
dc.contributor.author | Ryu, Yeonghwa | - |
dc.contributor.author | Yoon, Jae Woong | - |
dc.contributor.author | Hwang, Ho Sik | - |
dc.contributor.author | Song, In Seok | - |
dc.contributor.author | Lee, Chang Sun | - |
dc.contributor.author | Song, Seok Ho | - |
dc.date.accessioned | 2022-12-20T05:10:45Z | - |
dc.date.available | 2022-12-20T05:10:45Z | - |
dc.date.created | 2022-12-07 | - |
dc.date.issued | 2022-11 | - |
dc.identifier.issn | 2095-5545 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/172875 | - |
dc.description.abstract | We demonstrate a new type of multifocal and extended depth of focus (EDOF) intraocular lenses (IOLs) embedding mu m-thin geometric phase (GP) lens layers. As an emerging approach for lens phase design, the GP modulated IOLs outperform conventional diffractive IOLs in multifocality while completely avoiding the clinically undesirable demand for additional surface patterns to standard monofocal IOL designs. The number of foci and light splitting ratio of the GP IOLs are adjusted by changing the number of stacked GP layers and the thickness of each layer. Bifocal and trifocal GP IOLs are fabricated by radial alignment of anisotropic orientation in UV-curable liquid crystal polymers. After characterizing the defocus image and modulation transfer function of the GP IOLs, it is expected that GP IOLs will alleviate the most common problems associated with multifocal and EDOF IOLs, blurred vision and photic phenomena caused by light scattering and posterior capsule opacification. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | SPRINGERNATURE | - |
dc.title | Geometric-phase intraocular lenses with multifocality | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Jae Woong | - |
dc.contributor.affiliatedAuthor | Song, Seok Ho | - |
dc.identifier.doi | 10.1038/s41377-022-01016-y | - |
dc.identifier.scopusid | 2-s2.0-85141083411 | - |
dc.identifier.wosid | 000878164600001 | - |
dc.identifier.bibliographicCitation | LIGHT-SCIENCE & APPLICATIONS, v.11, no.1, pp.1 - 12 | - |
dc.relation.isPartOf | LIGHT-SCIENCE & APPLICATIONS | - |
dc.citation.title | LIGHT-SCIENCE & APPLICATIONS | - |
dc.citation.volume | 11 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 12 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.subject.keywordPlus | POSTERIOR CAPSULAR OPACIFICATION | - |
dc.subject.keywordPlus | SURFACE LIGHT-SCATTERING | - |
dc.subject.keywordPlus | NDYAG CAPSULOTOMY RATES | - |
dc.subject.keywordPlus | POLARIZATION | - |
dc.subject.keywordPlus | IMPLANTATION | - |
dc.subject.keywordPlus | FABRICATION | - |
dc.subject.keywordPlus | RANGE | - |
dc.identifier.url | https://www.nature.com/articles/s41377-022-01016-y | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.