Cited 0 time in
PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC (R) EBT FILM DOSIMETRY
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jeong, Hae Sun | - |
| dc.contributor.author | Han, Youngyih | - |
| dc.contributor.author | Kum, Oyeon | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Ju, Sang Gyu | - |
| dc.contributor.author | Shin, Jung Suk | - |
| dc.contributor.author | Kim, Jin Sung | - |
| dc.contributor.author | Park, Joo Hwan | - |
| dc.date.accessioned | 2022-12-20T10:49:40Z | - |
| dc.date.available | 2022-12-20T10:49:40Z | - |
| dc.date.issued | 2010-12 | - |
| dc.identifier.issn | 1738-5733 | - |
| dc.identifier.issn | 2234-358X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/173361 | - |
| dc.description.abstract | In this paper, a new approach using a pixel-based correction method was developed to fix the non-uniform responses of flat-bed type scanners used for radiochromic film dosimetry. In order to validate the method's performance, two cases were tested: the first consisted of simple dose distributions delivered by a single port; the second was a complicated dose distribution composed of multiple beams. In the case of the simple individual dose condition, ten different doses, from 8.3 cGy to 307.1 cGy, were measured, horizontal profiles were analyzed using the pixel-based correcton method and compared with results measured by an ionization chamber and results corrected using the existing correction method. A complicated inverse pyramid dose distribution was made by piling up four different field shapes, which were measured with GAFCHROMIC (R) EBT film and compared with the Monte Carlo calculation; as well as the dose distribution corrected using a conventional method. The results showed that a pixel-based correction method reduced dose difference from the reference measurement down to 1% in the flat close distribution region or 2 mm in a steep dose gradient region compared to the reference data, which were ionization chamber measurement data for simple cases and the MC computed data for the complicated case, with an exception for very low doses of less than about 10 cGy in the simple case. Therefore, the pixel-based scanner correction method is expected to enhance the accuracy of GAFCHROMIC (R) EBT film dosimetry, which is a widely used tool for two-dimensional dosimetry. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국원자력학회 | - |
| dc.title | PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC (R) EBT FILM DOSIMETRY | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5516/NET.2010.42.6.670 | - |
| dc.identifier.scopusid | 2-s2.0-78751546114 | - |
| dc.identifier.wosid | 000286023800006 | - |
| dc.identifier.bibliographicCitation | Nuclear Engineering and Technology, v.42, no.6, pp 670 - 679 | - |
| dc.citation.title | Nuclear Engineering and Technology | - |
| dc.citation.volume | 42 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 670 | - |
| dc.citation.endPage | 679 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001502576 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | RADIOCHROMIC FILM | - |
| dc.subject.keywordPlus | EBT FILM | - |
| dc.subject.keywordPlus | BEAM | - |
| dc.subject.keywordAuthor | EBT Film | - |
| dc.subject.keywordAuthor | Flat-Bed Scanner | - |
| dc.subject.keywordAuthor | Non-Uniform Dose Correction | - |
| dc.identifier.url | http://koreascience.or.kr/journal/view.jsp?issn=1738-5733&vol=42&no=6&sp=670 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.