Cited 0 time in
응급의료센터의 전원 주파수 자기장에 대한 노출
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 심상은 | - |
| dc.contributor.author | 최혁중 | - |
| dc.contributor.author | 강형구 | - |
| dc.contributor.author | 임태호 | - |
| dc.contributor.author | 강보승 | - |
| dc.date.accessioned | 2022-12-20T16:03:33Z | - |
| dc.date.available | 2022-12-20T16:03:33Z | - |
| dc.date.issued | 2010-08 | - |
| dc.identifier.issn | 1226-4334 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/174250 | - |
| dc.description.abstract | Purpose: We use many electronic devices for treating patients in our emergency department. Several studies have reported an association between electromagnetic field exposure and risk of cancer and other diseases. Our purpose was to measure the intensity of power-frequency magnetic fields in the emergency department and evaluate the conditions exceeded regulation guidelines for power-frequency magnetic fields. Methods: Extremely low frequency magnetic fields were measured at 78 ordinary working spots in our tertiary hospital’s emergency department (ED) and evaluated according to national regulatory guidelines and SWEDAC. Each spot was measured four times. During measurement, every electrical device in the emergency department was turned on. Results: The average intensity of the magnetic fields in our emergency department was 0.99±1.27 mG. The maximum intensity was 8.3 mG, which was found in the pediatric section. Conclusion: The power-frequency magnetic field intensities of the various sections of our ED did not exceed national regulatory guidelines. However, pediatric and the minor emergency section showed magnetic fields intensities far above 2 mG. We found these high values outside the pediatric and waiting sections, where the electrical cabinet panel was located. We conclude that the electrical cabinet panel should be shielded and that similar studies are needed for other emergency departments. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한응급의학회 | - |
| dc.title | 응급의료센터의 전원 주파수 자기장에 대한 노출 | - |
| dc.title.alternative | Exposure to Power Frequency Magnetic Fields in the Emergency Department | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 대한응급의학회지, v.21, no.4, pp 487 - 494 | - |
| dc.citation.title | 대한응급의학회지 | - |
| dc.citation.volume | 21 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 487 | - |
| dc.citation.endPage | 494 | - |
| dc.identifier.kciid | ART001473194 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Electromagnetic fields | - |
| dc.subject.keywordAuthor | Hospital emergency services | - |
| dc.subject.keywordAuthor | Environmental exposure | - |
| dc.identifier.url | http://www.riss.kr/search/detail/DetailView.do?p_mat_type=1a0202e37d52c72d&control_no=f70bd3b4b2db680f7ecd42904f0c5d65 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.