Cited 0 time in
A STUDY ON THE FAN EFFICIENCY DECREASE ON THE BACKWARD FLOW IN AN AXIAL FAN WITH ADJUSTABLE PITCH BLADE
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Hwa-Young | - |
| dc.contributor.author | Yoon, Sung-Hoon | - |
| dc.contributor.author | Moon, Seung Jae | - |
| dc.contributor.author | Lee, Jae-Heon | - |
| dc.contributor.author | Yoo, Ho-Seon | - |
| dc.contributor.author | Im, Yun-Chul | - |
| dc.date.accessioned | 2022-12-20T17:19:41Z | - |
| dc.date.available | 2022-12-20T17:19:41Z | - |
| dc.date.issued | 2010-06 | - |
| dc.identifier.issn | 2010-1325 | - |
| dc.identifier.issn | 2010-1333 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/174793 | - |
| dc.description.abstract | In this study, a numerical study has been carried out to analyze the factors of the efficiency decrease at backward flow situation in an axial fan with adjustable blades. The analysis is done with the pitch angle of 36° on the forward flow and of -26° on the backward flow. The numerical results show that the air flow rates of the pitch angle of 36° and -6° are calculated to be 285 cubic meter per min (CMM) and 212 CMM, respectively. The results are similar to the experimental results by Chang et al.1 The results had the maximum error of 10.6% compared with the experimental results. The fan efficiency decrease is caused by the fact that the axial fan used for this study was designed for the forward flow. As the results, the pitch angle of -26° has induced the recirculation around the impeller blade, impeller cover and downstream. This recirculation caused the large decrease in total pressure coefficient. This turned out to be the main cause of the efficiency decrease. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한설비공학회 | - |
| dc.title | A STUDY ON THE FAN EFFICIENCY DECREASE ON THE BACKWARD FLOW IN AN AXIAL FAN WITH ADJUSTABLE PITCH BLADE | - |
| dc.title.alternative | A STUDY ON THE FAN EFFICIENCY DECREASE ON THE BACKWARD FLOW IN AN AXIAL FAN WITH ADJUSTABLE PITCH BLADE | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1142/S2010132510000216 | - |
| dc.identifier.bibliographicCitation | International Journal of Air-Conditioning and Refrigeration, v.18, no.2, pp 101 - 107 | - |
| dc.citation.title | International Journal of Air-Conditioning and Refrigeration | - |
| dc.citation.volume | 18 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 101 | - |
| dc.citation.endPage | 107 | - |
| dc.identifier.kciid | ART001494741 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Hub | - |
| dc.subject.keywordAuthor | impeller | - |
| dc.subject.keywordAuthor | pitch angle | - |
| dc.subject.keywordAuthor | efficiency decrease | - |
| dc.identifier.url | https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO201027040782769&SITE=CLICK | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.