A STUDY ON THE FAN EFFICIENCY DECREASE ON THE BACKWARD FLOW IN AN AXIAL FAN WITH ADJUSTABLE PITCH BLADE

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Hwa-Young-
dc.contributor.authorYoon, Sung-Hoon-
dc.contributor.authorMoon, Seung Jae-
dc.contributor.authorLee, Jae-Heon-
dc.contributor.authorYoo, Ho-Seon-
dc.contributor.authorIm, Yun-Chul-
dc.date.accessioned2022-12-20T17:19:41Z-
dc.date.available2022-12-20T17:19:41Z-
dc.date.created2022-09-19-
dc.date.issued2010-06-
dc.identifier.issn2010-1325-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/174793-
dc.description.abstractIn this study, a numerical study has been carried out to analyze the factors of the efficiency decrease at backward flow situation in an axial fan with adjustable blades. The analysis is done with the pitch angle of 36° on the forward flow and of -26° on the backward flow. The numerical results show that the air flow rates of the pitch angle of 36° and -6° are calculated to be 285 cubic meter per min (CMM) and 212 CMM, respectively. The results are similar to the experimental results by Chang et al.1 The results had the maximum error of 10.6% compared with the experimental results. The fan efficiency decrease is caused by the fact that the axial fan used for this study was designed for the forward flow. As the results, the pitch angle of -26° has induced the recirculation around the impeller blade, impeller cover and downstream. This recirculation caused the large decrease in total pressure coefficient. This turned out to be the main cause of the efficiency decrease.-
dc.language영어-
dc.language.isoen-
dc.publisher대한설비공학회-
dc.titleA STUDY ON THE FAN EFFICIENCY DECREASE ON THE BACKWARD FLOW IN AN AXIAL FAN WITH ADJUSTABLE PITCH BLADE-
dc.title.alternativeA STUDY ON THE FAN EFFICIENCY DECREASE ON THE BACKWARD FLOW IN AN AXIAL FAN WITH ADJUSTABLE PITCH BLADE-
dc.typeArticle-
dc.contributor.affiliatedAuthorMoon, Seung Jae-
dc.identifier.doi10.1142/S2010132510000216-
dc.identifier.bibliographicCitationInternational Journal of Air-Conditioning and Refrigeration, v.18, no.2, pp.101 - 107-
dc.relation.isPartOfInternational Journal of Air-Conditioning and Refrigeration-
dc.citation.titleInternational Journal of Air-Conditioning and Refrigeration-
dc.citation.volume18-
dc.citation.number2-
dc.citation.startPage101-
dc.citation.endPage107-
dc.type.rimsART-
dc.identifier.kciidART001494741-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorHub-
dc.subject.keywordAuthorimpeller-
dc.subject.keywordAuthorpitch angle-
dc.subject.keywordAuthorefficiency decrease-
dc.identifier.urlhttps://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO201027040782769&SITE=CLICK-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Seung Jae photo

Moon, Seung Jae
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE