Determination of the Distal Dose Edge in a Human Phantom by Measuring the Prompt Gamma Distribution: A Monte Carlo Study
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Min, Chul Hee | - |
| dc.contributor.author | Lee, Han Rim | - |
| dc.contributor.author | Yeom, Yeon Su | - |
| dc.contributor.author | Cho, Sungkoo | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.date.accessioned | 2022-12-20T17:28:17Z | - |
| dc.date.available | 2022-12-20T17:28:17Z | - |
| dc.date.issued | 2010-06 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/174865 | - |
| dc.description.abstract | The close relationship between the proton dose distribution and the distribution of prompt gammas generated by proton-induced nuclear interactions along the path of protons in a water phantom was demonstrated by means of both Monte Carlo simulations and limited experiments. In order to test the clinical applicability of the method for determining the distal dose edge in a human body, a human voxel model, constructed based on a body-composition-approximated physical phantom, was used, after which the MCNPX code was used to analyze the energy spectra. and the prompt gamma yields from the major elements composing the human voxel model; finally, the prompt gamma distribution, generated from the voxel model and measured by using an array-type prompt gamma detection system, was calculated and compared with the proton close distribution. According to the results, effective prompt gammas were produced mainly by oxygen, and the specific energy of the prompt gammas, allowing for selective measurement, was found to be 4.44 MeV. The results also show that the distal dose edge in the human phantom, despite the heterogeneous composition and the complicated shape, can be determined by measuring the prompt gamma distribution with an array-type detection system. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Determination of the Distal Dose Edge in a Human Phantom by Measuring the Prompt Gamma Distribution: A Monte Carlo Study | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.56.2059 | - |
| dc.identifier.scopusid | 2-s2.0-77956376467 | - |
| dc.identifier.wosid | 000278830600028 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.56, no.6, pp 2059 - 2062 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 56 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 2059 | - |
| dc.citation.endPage | 2062 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.identifier.kciid | ART001451611 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordPlus | DETECTION SYSTEM | - |
| dc.subject.keywordPlus | PROTON-BEAM | - |
| dc.subject.keywordPlus | SIMULATION | - |
| dc.subject.keywordAuthor | Proton therapy | - |
| dc.subject.keywordAuthor | Prompt gamma | - |
| dc.subject.keywordAuthor | Distal dose edge | - |
| dc.subject.keywordAuthor | Human voxel model | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.identifier.url | https://www.jkps.or.kr/journal/view.html?volume=56&number=6(1)&spage=2059&year=2010 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.