Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Natural ventilation with traditional Korean opening in contemporary house

Full metadata record
DC Field Value Language
dc.contributor.authorKim, T. J.-
dc.contributor.authorPark, J. S.-
dc.date.accessioned2022-12-20T19:19:33Z-
dc.date.available2022-12-20T19:19:33Z-
dc.date.created2022-08-27-
dc.date.issued2010-01-
dc.identifier.issn0360-1323-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/175586-
dc.description.abstractIn this study, a natural ventilation opening was designed based on the traditional Korean opening to improve indoor environment on the contemporary house. The prototype of the opening was composed of three hanji papers and two air layers to improve airflow rate, and also to recovery heat lose. The performance of the heat recovery and airflows of the prototype was measured in laboratory, and the CFD simulation was used to verify its performance in the contemporary house. The airflow rate of the prototype is exponentially increased according to the pressure differences, and it ranges from 12.6 to 39.6 m(3)/m(2) h in 3-10 Pa, pressure difference. The total amount of heat recovery ranges from 47.8 to 67.7 W/m(2) in the prototype, and the heat recovery rate is about 25% at 10 Pa. In the CFD simulation, the prototypes were installed at 25% of the total window areas of the model house. The outside air was totally supplied through the prototypes at 67.2 m(3)/h in the model house, and it is equivalent to 0.2 h(-1) ventilation rate. The results show that the prototype is capable of providing natural ventilation even at low wind pressure, and also that it prevent cold draft in heating period. Further analysis of the ventilation performance including the thermal force is needed to apply the prototype to the contemporary house.-
dc.language영어-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleNatural ventilation with traditional Korean opening in contemporary house-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, J. S.-
dc.identifier.doi10.1016/j.buildenv.2009.05.016-
dc.identifier.scopusid2-s2.0-70249106024-
dc.identifier.wosid000271350500010-
dc.identifier.bibliographicCitationBUILDING AND ENVIRONMENT, v.45, no.1, pp.51 - 57-
dc.relation.isPartOfBUILDING AND ENVIRONMENT-
dc.citation.titleBUILDING AND ENVIRONMENT-
dc.citation.volume45-
dc.citation.number1-
dc.citation.startPage51-
dc.citation.endPage57-
dc.type.rimsART-
dc.type.docTypeArticle; Proceedings Paper-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Environmental-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.subject.keywordPlusPREDICTION-
dc.subject.keywordPlusENCLOSURE-
dc.subject.keywordAuthorNatural ventilation-
dc.subject.keywordAuthorTraditional Korean opening-
dc.subject.keywordAuthorWind pressure-
dc.subject.keywordAuthorHeat recovery-
dc.subject.keywordAuthorAirflow-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0360132309001334?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jun Seok photo

Park, Jun Seok
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE