Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

LCD versus CRT Monitors for Digital Mammography: A Comparison of Observer Performance for the Detection of Clustered Microcalcifications and Masses

Full metadata record
DC Field Value Language
dc.contributor.authorCha, Joo Hee-
dc.contributor.authorMoon, Woo Kyung-
dc.contributor.authorCho, Nariya-
dc.contributor.authorLee, Eun Hye-
dc.contributor.authorPark, Jeong Seon-
dc.contributor.authorJang, Mi Jung-
dc.date.accessioned2022-12-20T19:35:59Z-
dc.date.available2022-12-20T19:35:59Z-
dc.date.created2022-08-26-
dc.date.issued2009-12-
dc.identifier.issn0284-1851-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/175720-
dc.description.abstractBackground: There are two types of soft-copy display of digital mammograms, cathode-ray tube (CRT) and liquid-crystal display (LCD) monitors, and these present different resolutions and noise characteristics. Purpose: To compare observer performances for the detection of clustered microcalcifications and masses in digital mammograms, using LCD and CRT monitors. Material and Methods: Four radiologists evaluated 100 digital mammograms. Of these, 28 mammograms depicted clustered microcalcifications (12 benign, 16 malignant), 18 depicted masses (10 benign, eight malignant), and 54 depicted no apparent abnormality. The images were stored uncompressed as Digital Imaging and Communications in Medicine (DICOM) files and randomized for two sessions of soft-copy reading. The readers independently read all cases displayed on two 5-megapixel LCD and two CRT monitors with an interval of 3 months. Observers were asked to rate using a five-point scale the likelihoods of microcalcifications and masses independently. Receiver operating characteristic analysis was used to analyze results. Results: For the LCD and CRT monitors, average area-under-the-curve (A(z)) values for microcalcification detection were 0.977 (0.976, 0.970, 0.980, and 0.983 for the four readers) and 0.958 (0.910, 0.990, 0.976, 0.956), respectively. Corresponding A(z) values for masses were 0.971 (0.955, 0.990, 0.949, 0.989) and 0.944 (0.928, 0.966, 0.955, 0.925). No statistically significant difference was detected between the two monitor types (P > 0.05). Conclusion: The LCD and CRT monitors are comparable in terms of detecting clustered microcalcifications and masses in digital mammograms.-
dc.language영어-
dc.language.isoen-
dc.publisherSAGE PUBLICATIONS LTD-
dc.titleLCD versus CRT Monitors for Digital Mammography: A Comparison of Observer Performance for the Detection of Clustered Microcalcifications and Masses-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Jeong Seon-
dc.identifier.doi10.3109/02841850903246608-
dc.identifier.scopusid2-s2.0-73149092781-
dc.identifier.wosid000272986600004-
dc.identifier.bibliographicCitationACTA RADIOLOGICA, v.50, no.10, pp.1104 - 1108-
dc.relation.isPartOfACTA RADIOLOGICA-
dc.citation.titleACTA RADIOLOGICA-
dc.citation.volume50-
dc.citation.number10-
dc.citation.startPage1104-
dc.citation.endPage1108-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusLIQUID-CRYSTAL DISPLAY-
dc.subject.keywordPlusRAY TUBE MONITORS-
dc.subject.keywordPlusCHEST RADIOGRAPHS-
dc.subject.keywordPlusLESIONS-
dc.subject.keywordPlusFILM-
dc.subject.keywordAuthorBreast cancer-
dc.subject.keywordAuthorfull-field digital mammography (FFDM)-
dc.subject.keywordAuthormonitors-
dc.identifier.urlhttps://journals.sagepub.com/doi/10.3109/02841850903246608-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jeong Seon photo

Park, Jeong Seon
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE