Cited 0 time in
웨브를 볼트 접합한 보 플랜지 절취형 접합부의 회전능력평가
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 문기훈 | - |
| dc.contributor.author | 최병길 | - |
| dc.contributor.author | 황성훈 | - |
| dc.contributor.author | 한상환 | - |
| dc.date.accessioned | 2022-12-20T20:06:34Z | - |
| dc.date.available | 2022-12-20T20:06:34Z | - |
| dc.date.created | 2022-09-19 | - |
| dc.date.issued | 2009-11 | - |
| dc.identifier.issn | 1226-9107 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/175829 | - |
| dc.description.abstract | The purpose of this study is to propose a new design provisions for Reduced Beam Section with bolted web(RBS-B) connections for seismic applications at IMF system. This study is evaluating the rotation capacity of RBS-B connections. RBS connections are newly developed connections for high ductility and energy dissipation capacity. However some experimental specimens have been demonstrated that RBS-B connection was abnormally failed at the face of column and did not satisfy the enough plastic rotation capacity required for that of region of high seismicity. This experimental results were considered and limitation range of RBS-B connections was revised at IMF systems(ANSI/AISC 358-05). In this study, a number of parameters which influence the behavior of RBS-B connection were considered and proposed the new RBS-B design provisions for IMF system's limitation value by using dominated parameters at plastic capacity of RBS-B connection. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | 웨브를 볼트 접합한 보 플랜지 절취형 접합부의 회전능력평가 | - |
| dc.title.alternative | Evaluation of Rotation Capacity for Reduced Beam Section with Bolted Web | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 한상환 | - |
| dc.identifier.bibliographicCitation | 대한건축학회논문집 구조계, v.25, no.11, pp.71 - 78 | - |
| dc.relation.isPartOf | 대한건축학회논문집 구조계 | - |
| dc.citation.title | 대한건축학회논문집 구조계 | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 11 | - |
| dc.citation.startPage | 71 | - |
| dc.citation.endPage | 78 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART001392766 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Moment Resisting Frame | - |
| dc.subject.keywordAuthor | RBS-B Connection | - |
| dc.subject.keywordAuthor | Brittle Fracture | - |
| dc.subject.keywordAuthor | Rotation Capacity of Connections | - |
| dc.subject.keywordAuthor | 모멘트 저항 골조 | - |
| dc.subject.keywordAuthor | 웨브를 볼트로 접합한 보 플랜지 절취형 단면 접합부 | - |
| dc.subject.keywordAuthor | 취성파단 | - |
| dc.subject.keywordAuthor | 접합부의 회전성능 | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01287936 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.