| dc.description.abstract | The purpose of this study is to propose a new design provisions for Reduced Beam Section with bolted web(RBS-B) connections for seismic applications at IMF system. This study is divided two subjects. This is companion paper which is proposing the new design provisions of RBS-B connections. As a number of parameters which are activated to rotation capacity of RBS-B connections are existed complexly, those were analyzed by using experimental connection data. And it is demonstrated relations between parameters and rotation capacity at first study. So dominating influence factor, moment strength ratio (Mmax/Mplastic) for rotation capacity of RBS-B connections were used for new design equations to applicate at IMF system. In this study, the new design provisions of RBS-B connections were proposed for seismic application at IMF system and provided Mmax/Mplastic values regarding excess probability of total rotation angle at 0.02 radians respectively 16%, 50%, 84% of RBS-B connection. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | IMF 시스템에 적용하기 위한 RBS-B 접합부의 설계기준 제시 | - |
| dc.title.alternative | Proposing Design Provisions of RBS-B Connections for IMF System | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 한상환 | - |
| dc.identifier.bibliographicCitation | 대한건축학회논문집 구조계, v.25, no.11, pp.79 - 86 | - |
| dc.relation.isPartOf | 대한건축학회논문집 구조계 | - |
| dc.citation.title | 대한건축학회논문집 구조계 | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 11 | - |
| dc.citation.startPage | 79 | - |
| dc.citation.endPage | 86 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART001392768 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Moment Resisting Frame | - |
| dc.subject.keywordAuthor | RBS-B Connection | - |
| dc.subject.keywordAuthor | Plastic Rotation Capacity of Connections | - |
| dc.subject.keywordAuthor | Brittle Fracture | - |
| dc.subject.keywordAuthor | 모멘트 저항 골조 | - |
| dc.subject.keywordAuthor | 웨브를 볼트로 접합한 보 플랜지 절취형 단면 접합부 | - |
| dc.subject.keywordAuthor | 소성회전능력 | - |
| dc.subject.keywordAuthor | 취성파단 | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01287937 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.