Cited 0 time in
MONTE CARLO CALCULATIONS OF NEUTRON DOSE CONVERSION COEFFICIENTS FOR REFERENCE KOREAN MALE
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Jeong, Jong Hwi | - |
| dc.contributor.author | Cho, Sungkoo | - |
| dc.contributor.author | Choi, Sang Hyoun | - |
| dc.contributor.author | Chung, Min Suk | - |
| dc.date.accessioned | 2022-12-20T20:16:43Z | - |
| dc.date.available | 2022-12-20T20:16:43Z | - |
| dc.date.issued | 2009-11 | - |
| dc.identifier.issn | 0029-5450 | - |
| dc.identifier.issn | 1943-7471 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/175918 | - |
| dc.description.abstract | Neutron fluence-to-organ dose conversion coefficients (DCCs) were calculated for a Reference Korean-adjusted male voxel model, HDRK-Man, for some standard irradiation geometries of external neutron beams using the Monte Carlo radiation transport code MCNPX. The calculated values were compared with those for other models. The results show that HDRK-Man provides consistent results for the DCC values considering the differences in the voxel models. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Nuclear Society | - |
| dc.title | MONTE CARLO CALCULATIONS OF NEUTRON DOSE CONVERSION COEFFICIENTS FOR REFERENCE KOREAN MALE | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.13182/NT09-A9206 | - |
| dc.identifier.scopusid | 2-s2.0-73149099186 | - |
| dc.identifier.wosid | 000271320300017 | - |
| dc.identifier.bibliographicCitation | Nuclear Technology, v.168, no.2, pp 345 - 348 | - |
| dc.citation.title | Nuclear Technology | - |
| dc.citation.volume | 168 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 345 | - |
| dc.citation.endPage | 348 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | Monte Carlo methods | - |
| dc.subject.keywordPlus | Neutrons | - |
| dc.subject.keywordPlus | Neutron irradiation | - |
| dc.subject.keywordPlus | Calculated values | - |
| dc.subject.keywordPlus | Irradiation geometries | - |
| dc.subject.keywordPlus | Monte Carlo calculation | - |
| dc.subject.keywordPlus | Monte Carlo radiation transport code | - |
| dc.subject.keywordPlus | Neutron dose | - |
| dc.subject.keywordPlus | Neutron fluences | - |
| dc.subject.keywordPlus | Organ dose | - |
| dc.subject.keywordPlus | Voxel models | - |
| dc.subject.keywordAuthor | neutron dose | - |
| dc.subject.keywordAuthor | voxel model | - |
| dc.subject.keywordAuthor | Monte Carlo | - |
| dc.identifier.url | https://www.tandfonline.com/doi/abs/10.13182/NT09-A9206 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
