Cited 0 time in
CIS: A GUI-BASED SOFTWARE SYSTEM FOR MONTE CARLO SIMULATION OF COMPTON CAMERA
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Se Hyung | - |
| dc.contributor.author | Seo, Hee | - |
| dc.contributor.author | Park, Jin Hyung | - |
| dc.contributor.author | Park, Sung Ho | - |
| dc.contributor.author | Lee, Jae Sung | - |
| dc.contributor.author | Lee, Ju Hahn | - |
| dc.contributor.author | Lee, Chun Sik | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.date.accessioned | 2022-12-20T20:34:04Z | - |
| dc.date.available | 2022-12-20T20:34:04Z | - |
| dc.date.issued | 2009-10 | - |
| dc.identifier.issn | 0029-5450 | - |
| dc.identifier.issn | 1943-7471 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/176076 | - |
| dc.description.abstract | In the present study, a Compton camera simulator based on the GEANT4 detector simulation tool kit and MATLAB (TM) and designated the Compton Imaging Simulator (CIS), was developed. The software system encompasses a simulator, an image-reconstruction algorithm, and a data analysis tool. The computational time to obtain a sufficient number of Compton scattered data was dramatically reduced using the source-biasing and exponential transform techniques. Also, a four-dimensional Monte Carlo simulation capability was incorporated. A comparison of the simulation results with the experimental results shows that the CIS accurately simulates the Compton camera. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Nuclear Society | - |
| dc.title | CIS: A GUI-BASED SOFTWARE SYSTEM FOR MONTE CARLO SIMULATION OF COMPTON CAMERA | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.13182/NT09-A9101 | - |
| dc.identifier.scopusid | 2-s2.0-70350319782 | - |
| dc.identifier.wosid | 000270417700011 | - |
| dc.identifier.bibliographicCitation | Nuclear Technology, v.168, no.1, pp 55 - 60 | - |
| dc.citation.title | Nuclear Technology | - |
| dc.citation.volume | 168 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 55 | - |
| dc.citation.endPage | 60 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | GAMMA-CAMERA | - |
| dc.subject.keywordAuthor | Compton camera | - |
| dc.subject.keywordAuthor | GEANT4 | - |
| dc.subject.keywordAuthor | graphical user interface | - |
| dc.identifier.url | https://www.tandfonline.com/doi/abs/10.13182/NT09-A9101 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.