Cited 0 time in
APID공정 내 공정진단을 위한 dynamic - 관리도의 적용
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 안상우 | - |
| dc.contributor.author | 곽성근 | - |
| dc.contributor.author | 정영욱 | - |
| dc.contributor.author | 정무근 | - |
| dc.contributor.author | 박재우 | - |
| dc.date.accessioned | 2022-12-20T20:48:33Z | - |
| dc.date.available | 2022-12-20T20:48:33Z | - |
| dc.date.issued | 2009-09 | - |
| dc.identifier.issn | 2289-0971 | - |
| dc.identifier.issn | 2289-098X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/176206 | - |
| dc.description.abstract | Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to evaluate and monitor the effluent water quality (BOD5, SS, T-N, and T-P) and operating conditions (Influent, SVI, SRT, and HRT) as process capable and stable parameters for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent BOD5, SS, T-N, and T-P concentrations were 7.7, 5.6, 10.8, and 1.6 mg/L. Trend analysis of influent BOD5, SS, T-N, and T-P in APID process were illustrated that APID process need for more strong APID process management on the winter session, such as developing new intermediated aeration mode, operating methods, and managements strategy. At the application of control chart, the signal of uncommon effects at APID process was determined much higher existing control chart tntr conventional control chart in this study. These results indicate that conventional control chart has been collected and determined cleary signal at only stable situation. Therefore, newly developed APID process of dynamic control chart can be one of the useful tool for monitoring and management process. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국물환경학회 | - |
| dc.title | APID공정 내 공정진단을 위한 dynamic - 관리도의 적용 | - |
| dc.title.alternative | Application of Dynamic - Control Chart for Advanced Phase Isolation Ditch (APID) Process | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국물환경학회지, v.25, no.5, pp 704 - 712 | - |
| dc.citation.title | 한국물환경학회지 | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 704 | - |
| dc.citation.endPage | 712 | - |
| dc.identifier.kciid | ART001383117 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | BNR | - |
| dc.subject.keywordAuthor | Dynamic control chart | - |
| dc.subject.keywordAuthor | Nitrogen | - |
| dc.subject.keywordAuthor | Phosphorous | - |
| dc.subject.keywordAuthor | Process management | - |
| dc.identifier.url | https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200910103429202&SITE=CLICK | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.