Cited 0 time in
Estimation of blood pressure using photoplethysmography on the wrist
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Song, Soo Hwa | - |
| dc.contributor.author | Cho, J.S. | - |
| dc.contributor.author | Oh, Hong Sic | - |
| dc.contributor.author | Lee, Jong Shill | - |
| dc.contributor.author | Kim, In Young | - |
| dc.date.accessioned | 2022-12-20T20:50:37Z | - |
| dc.date.available | 2022-12-20T20:50:37Z | - |
| dc.date.issued | 2009-09 | - |
| dc.identifier.issn | 0276-6574 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/176229 | - |
| dc.description.abstract | Blood pressure measuring method using PPG signal is the one of many non-invasive blood pressure methods. In this study, we have studied a new method that estimates the blood pressure using wrist cuff and wrist PPG (Photoplethysmograph) signal. During the deflation of the wrist cuff pressure, the PPG pulse appears at certain point that is similar to Korotkoff sound. After the pulse appeared, the morphology of PPG pulses was changed into the certain shape. So, we use these points to estimate the blood pressure. For validation, the reference SBP and DBP are measured by auscultatory method at the left upper arm. Subjects were 13 non cardiac disease of man in their twenties. The result of this study, the mean difference of SBP and DBP, between auscultatory method and PPG analysis is 2.08 ± 5.07mmHg and 1.38 ± 7.86mmHg respectively. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.title | Estimation of blood pressure using photoplethysmography on the wrist | - |
| dc.type | Article | - |
| dc.identifier.scopusid | 2-s2.0-77952687518 | - |
| dc.identifier.bibliographicCitation | Computers in Cardiology, v.36, pp 741 - 744 | - |
| dc.citation.title | Computers in Cardiology | - |
| dc.citation.volume | 36 | - |
| dc.citation.startPage | 741 | - |
| dc.citation.endPage | 744 | - |
| dc.type.docType | Conference Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordPlus | Cardiac disease | - |
| dc.subject.keywordPlus | Cuff pressure | - |
| dc.subject.keywordPlus | Non-invasive | - |
| dc.subject.keywordPlus | Photoplethysmograph | - |
| dc.subject.keywordPlus | Photoplethysmography | - |
| dc.subject.keywordPlus | Upper arm | - |
| dc.subject.keywordPlus | Blood | - |
| dc.subject.keywordPlus | Cardiology | - |
| dc.subject.keywordPlus | Blood pressure | - |
| dc.identifier.url | https://ieeexplore.ieee.org/abstract/document/5445278/ | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
