Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

위전도 측정을 위한 전극간 부착거리에 관한 연구

Full metadata record
DC Field Value Language
dc.contributor.author한완택-
dc.contributor.author송인호-
dc.contributor.author김인영-
dc.date.accessioned2022-12-20T21:15:47Z-
dc.date.available2022-12-20T21:15:47Z-
dc.date.created2022-09-19-
dc.date.issued2009-08-
dc.identifier.issn1229-0807-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/176311-
dc.description.abstractCutaneous electrogastrography is the measurement of electrical activity of the stomach on the abdominal surface. The validity of cutaneous electrogastrography is dependent upon the quality of the recording technique. The locations of electrodes are an important issue. We examined the influences of the inter-electrode distance of bipolar leads on electrogastrography measurements. The sensitivity distributions of EGG leads were calculated based on a 2D body fat model and evaluated according to the region of interest sensitivity ratio (ROISR). We simulated the ROISR of the inter-electrode distance in relation to various body fat thicknesses. The distance between the electrodes was proportional to the distance between the ROI and the surface of the abdomen. The results imply that inter-electrode distance can be applied in electrogastrography according to human body fat thickness.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한의용생체공학회-
dc.title위전도 측정을 위한 전극간 부착거리에 관한 연구-
dc.title.alternativeInfluences of Inter-electrode Distance on Electrogastrography Measurements-
dc.typeArticle-
dc.contributor.affiliatedAuthor김인영-
dc.identifier.bibliographicCitation의공학회지, v.30, no.4, pp.341 - 346-
dc.relation.isPartOf의공학회지-
dc.citation.title의공학회지-
dc.citation.volume30-
dc.citation.number4-
dc.citation.startPage341-
dc.citation.endPage346-
dc.type.rimsART-
dc.identifier.kciidART001368978-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorElectrogastrography-
dc.subject.keywordAuthorSurface electrodes-
dc.subject.keywordAuthorbipolar recording-
dc.subject.keywordAuthorsurface potential-
dc.subject.keywordAuthorfat thickness-
dc.subject.keywordAuthorElectrogastrography-
dc.subject.keywordAuthorSurface electrodes-
dc.subject.keywordAuthorbipolar recording-
dc.subject.keywordAuthorsurface potential-
dc.subject.keywordAuthorfat thickness-
dc.identifier.urlhttps://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200931559971969&SITE=CLICK-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, In Young photo

Kim, In Young
COLLEGE OF MEDICINE (DEPARTMENT OF BIOMEDICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE