Detailed Information

Cited 0 time in webofscience Cited 27 time in scopus
Metadata Downloads

New mesh-type phantoms and their dosimetric applications, including emergencies

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorYeom, YS-
dc.contributor.authorNguyen, TT-
dc.contributor.authorHan, MC-
dc.contributor.authorChoi, C-
dc.contributor.authorLee, H-
dc.contributor.authorHan, H-
dc.contributor.authorShin, B-
dc.contributor.authorLee, JK-
dc.contributor.authorKim, HS-
dc.contributor.authorZankl, Maria Agnes-
dc.contributor.authorPetoussi-Henss, N-
dc.contributor.authorBolch, WE-
dc.contributor.authorLee, C-
dc.contributor.authorChung, BS-
dc.contributor.authorQiu, R-
dc.contributor.authorEckerman, K-
dc.date.accessioned2021-08-02T13:51:11Z-
dc.date.available2021-08-02T13:51:11Z-
dc.date.created2021-05-13-
dc.date.issued2018-04-
dc.identifier.issn0146-6453-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/17664-
dc.description.abstractCommittee 2 of the International Commission on Radiological Protection (ICRP) has constructed mesh-type adult reference computational phantoms by converting the voxel-type ICRP Publication 110 adult reference computational phantoms to a high-quality mesh format, and adding those tissues that were below the image resolution of the voxel phantoms and therefore not included in the Publication 110 phantoms. The new mesh phantoms include all the necessary source and target tissues for effective dose calculations, including the 8?40-?m-thick target layers of the alimentary and respiratory tract organs, thereby obviating the need for supplemental organ-specific stylised models (e.g. respiratory airways, alimentary tract organ walls and stem cell layers, lens of the eye, and skin basal layer). To see the impact of the new mesh-type reference phantoms, dose coefficients for some selected external and internal exposures were calculated and compared with the current reference values in ICRP Publications 116 and 133, which were calculated by employing the Publication 110 phantoms and the supplemental stylised models. The new mesh phantoms were also used to calculate dose coefficients for industrial radiography sources near the body, which can be used to estimate the organ doses of the worker who is accidentally exposed by an industrial radiography source; in these calculations, the mesh phantoms were deformed to reflect the size of the worker, and also to evaluate the effect of posture on dose coefficients.-
dc.language영어-
dc.language.isoen-
dc.publisherSAGE Publications Ltd-
dc.titleNew mesh-type phantoms and their dosimetric applications, including emergencies-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1177/0146645318756231-
dc.identifier.scopusid2-s2.0-85045304177-
dc.identifier.bibliographicCitationAnnals of the ICRP, v.47, no.03, pp.45 - 62-
dc.relation.isPartOfAnnals of the ICRP-
dc.citation.titleAnnals of the ICRP-
dc.citation.volume47-
dc.citation.number03-
dc.citation.startPage45-
dc.citation.endPage62-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusadult mesh type reference computational phantoms-
dc.subject.keywordPlusArticle-
dc.subject.keywordPluscomparative study-
dc.subject.keywordPlusdosimetry-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusMonte Carlo method-
dc.subject.keywordPlusradiation exposure-
dc.subject.keywordPlusradiography-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusanalysis-
dc.subject.keywordPlusimaging phantom-
dc.subject.keywordPlusinternational cooperation-
dc.subject.keywordPlusprocedures-
dc.subject.keywordPlusradiation protection-
dc.subject.keywordPlusradiometry-
dc.subject.keywordPlusreference value-
dc.subject.keywordPlusstandards-
dc.subject.keywordPlusAdult-
dc.subject.keywordPlusHumans-
dc.subject.keywordPlusInternational Agencies-
dc.subject.keywordPlusPhantoms, Imaging-
dc.subject.keywordPlusRadiation Exposure-
dc.subject.keywordPlusRadiation Protection-
dc.subject.keywordPlusRadiometry-
dc.subject.keywordPlusReference Values-
dc.subject.keywordAuthorDose coefficient-
dc.subject.keywordAuthorMesh-type phantom-
dc.subject.keywordAuthorMonte Carlo-
dc.subject.keywordAuthorReference ICRP phantom-
dc.subject.keywordAuthorVoxel-type phantom-
dc.identifier.urlhttps://journals.sagepub.com/doi/10.1177/0146645318756231-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE