| dc.contributor.author | Jeon, Woo Jae | - |
| dc.contributor.author | Kim, Kyoung Hun | - |
| dc.contributor.author | Suh, Jung Kook | - |
| dc.contributor.author | Cho, Sang Yun | - |
| dc.date.accessioned | 2022-12-20T22:21:11Z | - |
| dc.date.available | 2022-12-20T22:21:11Z | - |
| dc.date.issued | 2009-05 | - |
| dc.identifier.issn | 0003-2999 | - |
| dc.identifier.issn | 1526-7598 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/176812 | - |
| dc.description.abstract | BACKGROUND: The use of remifentanil before propofol administration facilitates the insertion of the Laryngeal Mask Airway. We designed the present study to determine whether remifentanil would also create more suitable conditions for providing Cobra Perilaryngeal airway (CobraPLA) insertion when administered with propofol. METHODS: Both remifentanil and propofol were given as effect-site target-controlled infusions. There were four groups of 25 patients each. The propofol effect-site concentration was set at 6 mu g/mL in all groups. Group RI received a target effect-site remifentanil concentration of 1 ng/mL, Group R2 received remifentanil at 2 ng/mL, Group R3 received remifentanil at 3 ng/mL, and Group R4 received remifentanil at 4 ng/mL before the induction of anesthesia with propofol. The ease of insertion of CobraPLA was graded by the following 3-point scale: Grade 1, excellent, no response to CobraPLA insertion; Grade 2, acceptable, gagging or swallowing with insertion of CobraPLA; Grade 3, poor, unable to open mouth or biting upon insertion of CobraPLA. RESULTS: The most patients ranked as excellent for the first CobraPLA insertion (Grade 1) were found in Group R4, which was significantly higher than Groups R1 and R2 (P < 0.01), whereas no significant difference was found when compared with Group R3. The duration of apnea showed a significant dose-related increase (P < 0.01), especially between Group R2 (median 2.95 min) and R3 (median 7.9 min), but there wash no significant difference between Groups R3 and R4. The incidence of hypotension in Group R4 within 1 min after insertion of CobraPLA was significantly more than for Groups R1 and R2 (P < 0.01). No significant differences could be found between the incidence of hypotension between Group M and the other groups. The incidence of hypertension at 1 min postinsertion was significantly more common in Groups R1 and R2 than Groups R3 and R4 (P < 0.01). CONCLUSION: An effect-site concentration of remifentanil of 2 ng/mL provides excellent conditions for insertion of the CobraPLA on the first attempt with minimal hemodynamic perturbations and a shorter duration of apnea. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Lippincott Williams & Wilkins Ltd. | - |
| dc.title | The Use of Remifentanil to Facilitate the Insertion of the Cobra Perilaryngeal Airway | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1213/ane.0b013e31819e0248 | - |
| dc.identifier.scopusid | 2-s2.0-65349146478 | - |
| dc.identifier.wosid | 000265422300025 | - |
| dc.identifier.bibliographicCitation | Anesthesia and Analgesia, v.108, no.5, pp 1505 - 1509 | - |
| dc.citation.title | Anesthesia and Analgesia | - |
| dc.citation.volume | 108 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 1505 | - |
| dc.citation.endPage | 1509 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Anesthesiology | - |
| dc.relation.journalWebOfScienceCategory | Anesthesiology | - |
| dc.subject.keywordPlus | LARYNGEAL MASK AIRWAY | - |
| dc.subject.keywordPlus | TRACHEAL INTUBATION | - |
| dc.subject.keywordPlus | PROPOFOL | - |
| dc.subject.keywordPlus | VENTILATION | - |
| dc.subject.keywordPlus | ANESTHESIA | - |
| dc.subject.keywordPlus | TUBE | - |
| dc.identifier.url | https://journals.lww.com/anesthesia-analgesia/Fulltext/2009/05000/The_Use_of_Remifentanil_to_Facilitate_the.25.aspx | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.