Cited 0 time in
Rapid Detection of Salmonella enteritidis in Pork Samples with Impedimetric Biosensor: Effect of Electrode Spacing on Sensitivity
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Giyoung | - |
| dc.contributor.author | Moon, Ji Hea | - |
| dc.contributor.author | Hahm, Bung-Kwon | - |
| dc.contributor.author | Morgan, Mark | - |
| dc.contributor.author | Bhunia, Arun | - |
| dc.contributor.author | Om, Ae Son | - |
| dc.date.accessioned | 2022-12-20T23:35:25Z | - |
| dc.date.available | 2022-12-20T23:35:25Z | - |
| dc.date.issued | 2009-02 | - |
| dc.identifier.issn | 1226-7708 | - |
| dc.identifier.issn | 2092-6456 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/177309 | - |
| dc.description.abstract | Frequent outbreaks of foodborne illness have been increasing the awareness of food safety. Conventional methods for pathogen detection and identification are labor-intensive and take days to complete. Some immunological, rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown potential for the rapid detection of foodborne pathogens. In this study, ail impedimetric biosensor was developed for rapid detection of Salmonella entritidis in food sample. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using a semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on neutravidin-biotin binding on the surface of the IME to form an active sensing layer. To evaluate the effect of electrode gap on sensitivity of the sensor, 3 types of sensors with different electrode gap sizes (2, 5, and 10 pin) were fabricated and tested. The impedimetric biosensor could detect 10(3) CFU/mL of Salmonella in pork meat extract with an incubation time of 5 min. This method may provide a simple, rapid, and sensitive method to detect foodborne pathogens. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국식품과학회 | - |
| dc.title | Rapid Detection of Salmonella enteritidis in Pork Samples with Impedimetric Biosensor: Effect of Electrode Spacing on Sensitivity | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.scopusid | 2-s2.0-79954562908 | - |
| dc.identifier.wosid | 000263843200015 | - |
| dc.identifier.bibliographicCitation | Food Science and Biotechnology, v.18, no.1, pp 89 - 94 | - |
| dc.citation.title | Food Science and Biotechnology | - |
| dc.citation.volume | 18 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 89 | - |
| dc.citation.endPage | 94 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001321327 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Food Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Food Science & Technology | - |
| dc.subject.keywordPlus | AUTOMATED DETECTION | - |
| dc.subject.keywordPlus | TYPHIMURIUM | - |
| dc.subject.keywordAuthor | biosensor | - |
| dc.subject.keywordAuthor | Salmonella | - |
| dc.subject.keywordAuthor | interdigitated microelectrode | - |
| dc.subject.keywordAuthor | impedimetric | - |
| dc.subject.keywordAuthor | immunosensor | - |
| dc.identifier.url | https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO200909651055645&SITE=CLICK | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
