Lab-scale study on the application of In-Adit-Sulfate-Reducing System for AMD control
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ji, Sang-Woo | - |
| dc.contributor.author | Kim, Sun Joon | - |
| dc.date.accessioned | 2022-12-21T00:22:05Z | - |
| dc.date.available | 2022-12-21T00:22:05Z | - |
| dc.date.issued | 2008-12 | - |
| dc.identifier.issn | 0304-3894 | - |
| dc.identifier.issn | 1873-3336 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/177640 | - |
| dc.description.abstract | In a study of the 29 operating passive systems for acid mine drainage (AMD) treatment. 19 systems showed various performance problems. Some systems showed very low efficiency even without visible leakage or overflow. Though systems show fairly good efficiency in metal removal (mainly iron) and pH control, sulfate removal rates were very low which indicates the possibility of very poor sulfate reductions by Sulfate Reducing Bacteria (SRB). As an alternative method. In-Adit-Sulfate-Reducing System (IASRS), the method of placing the SAPS inside the adit, to have temperature constant at about 15 degrees C, was suggested. Lab-scale model experiments of IASRS were carried out. The models 1 and 2 were run at 15 degrees C and 25 degrees C. respectively. The model 1 contained about a half of COD in the beginning of the operation than that of model 2. Metal removal ratios were higher than 90% in both systems. Both systems showed the sulfate removal ratios of 23% and 27%. respectively, which were still considerably low, even though higher than those of presently operating systems. However. since the synthetic AMD used was very low in pH (2.8) and very high in sulfate concentration, if some suggested modifications were applied to the standard design, it is presumed that the Sulfate removal ratio would have increased. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Lab-scale study on the application of In-Adit-Sulfate-Reducing System for AMD control | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.jhazmat.2008.03.059 | - |
| dc.identifier.scopusid | 2-s2.0-54549120573 | - |
| dc.identifier.wosid | 000261255200027 | - |
| dc.identifier.bibliographicCitation | Journal of Hazardous Materials, v.160, no.2-3, pp 441 - 447 | - |
| dc.citation.title | Journal of Hazardous Materials | - |
| dc.citation.volume | 160 | - |
| dc.citation.number | 2-3 | - |
| dc.citation.startPage | 441 | - |
| dc.citation.endPage | 447 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
| dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
| dc.subject.keywordPlus | ACID-MINE DRAINAGE | - |
| dc.subject.keywordPlus | BIOLOGICAL TREATMENT | - |
| dc.subject.keywordAuthor | Acid mine drainage (AMD) | - |
| dc.subject.keywordAuthor | SAPS | - |
| dc.subject.keywordAuthor | In-Adit-Sulfate-Reducing System (IASRS) | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S030438940800366X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.