Robust Raman measurement of hydrogen peroxide directly through plastic containers under the change of bottle position and its long-term prediction reproducibility

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Minjung-
dc.contributor.authorChung, Hoeil-
dc.contributor.authorKemper, Mark S.-
dc.date.accessioned2022-12-21T00:34:05Z-
dc.date.available2022-12-21T00:34:05Z-
dc.date.issued2008-11-
dc.identifier.issn0731-7085-
dc.identifier.issn1873-264X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/177744-
dc.description.abstractHydrogen peroxide concentration in antiseptic solutions has been non-destructively measured with the use of wide area illumination (WAI) scheme by applying a laser beam directly through a plastic container. The prediction accuracy was comparable to that from the use of quartz cell instead of a plastic bottle as well as near-infrared (NIR) prediction result in the previous study. Although the position of a plastic bottle was artificially changed in three-dimensional directions up to +/- 10 mm to simulate real situation of practical measurement, the prediction accuracy was not degraded within +/- 5 mm positional variation. This robust prediction performance was powered by the merits of WAI scheme that could provide improved reproducibility by illuminating large sample areas as well as less sensitivity of sample placement by the design of long focal length. Moreover, the prediction accuracy was successfully maintained over along period of time. Finally, the prediction was also reproducible under the situation of laser power variation. The overall results demonstrate that WAI Raman scheme can provide robust and non-destructive quantitative analysis for not only hydrogen peroxide in antiseptic solution, but also other active pharmaceutical ingredients in diverse containers.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleRobust Raman measurement of hydrogen peroxide directly through plastic containers under the change of bottle position and its long-term prediction reproducibility-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/j.jpba.2008.05.029-
dc.identifier.scopusid2-s2.0-53049090042-
dc.identifier.wosid000260196500012-
dc.identifier.bibliographicCitationJournal of Pharmaceutical and Biomedical Analysis, v.48, no.3, pp 592 - 597-
dc.citation.titleJournal of Pharmaceutical and Biomedical Analysis-
dc.citation.volume48-
dc.citation.number3-
dc.citation.startPage592-
dc.citation.endPage597-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaPharmacology & Pharmacy-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryPharmacology & Pharmacy-
dc.subject.keywordPlusINFRARED-SPECTROSCOPY-
dc.subject.keywordPlusQUANTITATIVE-ANALYSIS-
dc.subject.keywordPlusACTIVE INGREDIENT-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthorHydrogen peroxide-
dc.subject.keywordAuthorRaman spectroscopy-
dc.subject.keywordAuthorNon-invasive analysis-
dc.subject.keywordAuthorWide area illumination-
dc.subject.keywordAuthorPAT-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0731708508003312?via%3Dihub#aep-section-id24-
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE