Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

AID - A Novel Method for Improving the Imaging Resolution of a Table-Top Compton Camera

Full metadata record
DC Field Value Language
dc.contributor.authorSeo, Hee-
dc.contributor.authorLee, Se Hyung-
dc.contributor.authorJeong, Jong Hwi-
dc.contributor.authorLee, Ju Hahn-
dc.contributor.authorLee, Chun Sik-
dc.contributor.authorLee, Jae Sung-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2022-12-21T01:10:18Z-
dc.date.available2022-12-21T01:10:18Z-
dc.date.created2022-08-26-
dc.date.issued2008-10-
dc.identifier.issn0018-9499-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/177863-
dc.description.abstractA Compton camera is usually composed of a scatterer detector and an absorber detector. The interaction position resolution of the absorber detector is the critical or limiting detector parameter that most seriously affects the imaging resolution of the table-top Compton camera currently under development in our group. Currently, it is assumed that all interactions occur at the centers of the detector segments of the absorber detector (25-segmented germanium detector), which is a simple but obviously not the best practice, considering that the interaction depths of the photons in the absorber detector, especially of low-energy photons, are not distributed uniformly. More photons have interaction in the front region of the detector due to the limited penetrating depth of the photons. Therefore, the present study developed a novel, "average interaction depth (AID)" method, which improves the imaging resolution of Compton camera by additionally considering the average interaction depth of the incident photon in the absorber detector. Simulations with Geant4 showed that the imaging resolution of the Compton camera can be significantly improved by using the AID method. For example, the resolution for a 511 keV gamma point source was improved from 9.9 mm to 7.6 mm in full width half maximum (FWRM). For a 364 keV gamma point source, the improvement was even more significant from 11.4 mm to 7.2 mm.-
dc.language영어-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titleAID - A Novel Method for Improving the Imaging Resolution of a Table-Top Compton Camera-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1109/TNS.2008.2000777-
dc.identifier.scopusid2-s2.0-57849095723-
dc.identifier.wosid000262015700012-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.55, no.5, pp.2527 - 2530-
dc.relation.isPartOfIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.titleIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.volume55-
dc.citation.number5-
dc.citation.startPage2527-
dc.citation.endPage2530-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusSTRIP DETECTOR-
dc.subject.keywordPlusGAMMA-CAMERA-
dc.subject.keywordPlusTELESCOPE-
dc.subject.keywordAuthorAbsorber-
dc.subject.keywordAuthorCompton camera-
dc.subject.keywordAuthorGeant4-
dc.subject.keywordAuthorinteraction depth-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/4689329-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE