광봉을 이용한 기관내 삽관 시 냄새맡기 자세와 중립 자세의 비교
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 서정국 | - |
| dc.contributor.author | 김남우 | - |
| dc.contributor.author | 전우재 | - |
| dc.contributor.author | 염종훈 | - |
| dc.contributor.author | 신우종 | - |
| dc.contributor.author | 김경헌 | - |
| dc.contributor.author | 조상윤 | - |
| dc.date.accessioned | 2022-12-21T04:44:21Z | - |
| dc.date.available | 2022-12-21T04:44:21Z | - |
| dc.date.issued | 2008-01 | - |
| dc.identifier.issn | 2005-6419 | - |
| dc.identifier.issn | 2005-7563 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/179056 | - |
| dc.description.abstract | The sniffing position is recommended for optimal glottic visualization under direct laryngoscopy. However, there is no study assessing whether sniffing position is superior to a neutral position during lightwand-guided intubation. This prospective, randomized study was performed to compare facilitation of lightwand-guided intubation between the sniffing and neutral positions. Methods:The study included 180 patients with normal cervical spines requiring tracheal intubation for elective surgery. Patients were randomly allocated into two groups: neutral or sniffing position. Mallampati class, mouth opening distance, thyromental distance, and laryngeal view grade were measured. A lightwand railroaded with an endotracheal tube was bent 90o at 5 cm from the distal end for both groups. Time to intubation, success rate and intubation time for the first attempt, hydrodynamic changes, and BIS values were recorded. Results:There were no significant differences in time to intubation, success rate and intubation time of the first trial, hydrodynamic changes, or BIS values between the two positions. Conclusions:Routine use of the sniffing position does not provide any advantage over the neutral position during lightwand-guided intubation. | - |
| dc.format.extent | 5 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한마취통증의학회 | - |
| dc.title | 광봉을 이용한 기관내 삽관 시 냄새맡기 자세와 중립 자세의 비교 | - |
| dc.title.alternative | Randomized Study Comparing the Sniffing position with Neutral Position for Lightwand Intubation | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.4097/kjae.2008.54.1.25 | - |
| dc.identifier.bibliographicCitation | Korean Journal of Anesthesiology, v.54, no.1, pp 25 - 29 | - |
| dc.citation.title | Korean Journal of Anesthesiology | - |
| dc.citation.volume | 54 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 25 | - |
| dc.citation.endPage | 29 | - |
| dc.identifier.kciid | ART001238839 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | lightwand | - |
| dc.subject.keywordAuthor | neutral position | - |
| dc.subject.keywordAuthor | sniffing position. | - |
| dc.identifier.url | https://ekja.org/journal/view.php?doi=10.4097/kjae.2008.54.1.25 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.