Cited 0 time in
Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Min, Chul Hee | - |
| dc.contributor.author | Kim, J. W. | - |
| dc.contributor.author | Youn, Min Young | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.date.accessioned | 2022-12-21T06:41:23Z | - |
| dc.date.available | 2022-12-21T06:41:23Z | - |
| dc.date.issued | 2007-09 | - |
| dc.identifier.issn | 0168-9002 | - |
| dc.identifier.issn | 1872-9576 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/179669 | - |
| dc.description.abstract | In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(T1) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, the PGS system was tested with a 38 MeV proton beam at the Korea cancer center hospital (KCCH). The experiment was also simulated, using a Monte Carlo particle transport simulation code, MCNPX. Our result is very encouraging, showing that there is a clear correlation between the distribution of the prompt gammas and the location of the distal dose edge for the 38 MeV proton beam. According to our result, we believe that the location of the distal dose edge can be determined within 1-2 mm from the distribution of the prompt gammas. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.nima.2007.05.235 | - |
| dc.identifier.scopusid | 2-s2.0-34548227965 | - |
| dc.identifier.wosid | 000249741300144 | - |
| dc.identifier.bibliographicCitation | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v.580, no.1, pp 562 - 565 | - |
| dc.citation.title | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | - |
| dc.citation.volume | 580 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 562 | - |
| dc.citation.endPage | 565 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Physics, Nuclear | - |
| dc.relation.journalWebOfScienceCategory | Physics, Particles & Fields | - |
| dc.subject.keywordAuthor | proton therapy | - |
| dc.subject.keywordAuthor | dosimetry | - |
| dc.subject.keywordAuthor | proton range | - |
| dc.subject.keywordAuthor | prompt gammas | - |
| dc.subject.keywordAuthor | Monte Carlo | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0168900207011230?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
