Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optimization of a table-top Compton camera system by Monte Carlo simulation

Full metadata record
DC Field Value Language
dc.contributor.authorAn, So Hyun-
dc.contributor.authorSeo, Hee-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2022-12-21T06:42:02Z-
dc.date.available2022-12-21T06:42:02Z-
dc.date.created2022-08-26-
dc.date.issued2007-09-
dc.identifier.issn0168-9002-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/179674-
dc.description.abstractThe Compton camera, which is a very promising imaging device in nuclear medicine and molecular imaging, is characterized by the capability of 3-D imaging of the radioisotope distribution from a fixed position, almost no limitation on the energy of gamma sources (100 keV-10 MeV), a multiple radioisotope tracing capability, and high imaging sensitivity. Our table-top Compton camera consists of a double-sided silicon strip detector (5 x 5 x 0.15 cm(3), 16 x 16 strips) and a 25-segmented germanium detector (5 x 5 x 2 cm(3), 5 x 5 segments). In this study, the table-top Compton camera was optimized with the GEANT4 detector simulation toolkit in order to maximize its performance for F-18. The scatterer-to-absorber distance and scatterer-to-absorber angle were investigated for their utility as optimization parameters. Our results show that the optimal performance of the Compton camera is achieved when the scatterer and absorber are positioned in parallel and 7-13 cm apart.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.titleOptimization of a table-top Compton camera system by Monte Carlo simulation-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1016/j.nima.2007.05.076-
dc.identifier.scopusid2-s2.0-34548227031-
dc.identifier.wosid000249741300044-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.580, no.1, pp.169 - 172-
dc.relation.isPartOfNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume580-
dc.citation.number1-
dc.citation.startPage169-
dc.citation.endPage172-
dc.type.rimsART-
dc.type.docTypeArticle; Proceedings Paper-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Nuclear-
dc.relation.journalWebOfScienceCategoryPhysics, Particles & Fields-
dc.subject.keywordAuthorCompton camera-
dc.subject.keywordAuthormedical imaging-
dc.subject.keywordAuthoroptimization-
dc.subject.keywordAuthorMonte Carlo-
dc.subject.keywordAuthorGEANT4-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S016890020700900X?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE