Cited 0 time in
Validated LC-MS/MS method for quantification of gabapentin in human plasma: application to pharmacokinetic and bioequivalence studies in Korean volunteers
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Jin-Hee | - |
| dc.contributor.author | Jhee, Ok-Hwa | - |
| dc.contributor.author | Park, Song-Hee | - |
| dc.contributor.author | Lee, Jung-Sik | - |
| dc.contributor.author | Lee, Min-Ho | - |
| dc.contributor.author | Shaw, Leslie M. | - |
| dc.contributor.author | Kim, Kwang-Hyun | - |
| dc.contributor.author | Lee, Jong-Ho | - |
| dc.contributor.author | Kim, Yong-Seok | - |
| dc.contributor.author | Kang, Ju-Seop | - |
| dc.date.accessioned | 2022-12-21T06:59:26Z | - |
| dc.date.available | 2022-12-21T06:59:26Z | - |
| dc.date.issued | 2007-08 | - |
| dc.identifier.issn | 0269-3879 | - |
| dc.identifier.issn | 1099-0801 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/179788 | - |
| dc.description.abstract | A sensitive validated liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for gabapentin (GB) in human plasma has been developed and applied to pharmacokinetic (PK) and bioequivalence (BE) studies in human. In a randomized crossover design with a 1 -week period, each subject received a 300 mg GB capsule. The procedure involves a simple protein precipitation with acetonitrile and separated by LC with a Gemini C-18 column using acetonitrile-10 mM ammonium acetate (20:80, v/v, pH 3.2) as mobile phase. The GB and internal standard [(S)-(+)-alpha-aminocyclohexanepropionic acid hydrate] were analyzed using an LC-API 2000 MS/MS in multiple reaction monitoring mode. The ionization was optimized using ESI(+) and selectivity was achieved using MS/MS analysis, m/z 172.0 -> 154.0 and m/z 172.0 -> 126.0 for GB and IS, respectively. The assay exhibited good linearity over a working range of 20-5000 ng/mL for GB in human plasma with a lower limit of quantitation of 20 ng/mL. No endogenous compounds were found to interfere with the analysis. The accuracy and precision were shown for concentrations over the standard ranges. This method was successfully applied for the PK and BE studies by analysis of blood samples taken up to 36 h after an oral dose of 300 mg of GB in 24 healthy volunteers. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | John Wiley & Sons Inc. | - |
| dc.title | Validated LC-MS/MS method for quantification of gabapentin in human plasma: application to pharmacokinetic and bioequivalence studies in Korean volunteers | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1002/bmc.826 | - |
| dc.identifier.scopusid | 2-s2.0-34547662485 | - |
| dc.identifier.wosid | 000248500900008 | - |
| dc.identifier.bibliographicCitation | Biomedical Chromatography, v.21, no.8, pp 829 - 835 | - |
| dc.citation.title | Biomedical Chromatography | - |
| dc.citation.volume | 21 | - |
| dc.citation.number | 8 | - |
| dc.citation.startPage | 829 | - |
| dc.citation.endPage | 835 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Pharmacology & Pharmacy | - |
| dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
| dc.relation.journalWebOfScienceCategory | Biochemistry & Molecular Biology | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Pharmacology & Pharmacy | - |
| dc.subject.keywordPlus | TANDEM MASS-SPECTROMETRY | - |
| dc.subject.keywordPlus | SOLID-PHASE EXTRACTION | - |
| dc.subject.keywordPlus | LIQUID-CHROMATOGRAPHY | - |
| dc.subject.keywordPlus | CLINICAL PHARMACOKINETICS | - |
| dc.subject.keywordPlus | SERUM | - |
| dc.subject.keywordPlus | ABSORPTION | - |
| dc.subject.keywordAuthor | LC-MS/MS | - |
| dc.subject.keywordAuthor | gabapentin | - |
| dc.subject.keywordAuthor | pharmacokinetics | - |
| dc.subject.keywordAuthor | bioequivalence study | - |
| dc.identifier.url | https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/bmc.826 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
