Evaluation of rating factors for steel cable-stayed bridges using load and resistant factor rating
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Dong Ho | - |
dc.contributor.author | Yoo, Hoon | - |
dc.contributor.author | Shin, Jay In | - |
dc.contributor.author | Lee, Joung Sun | - |
dc.date.accessioned | 2022-12-21T08:03:43Z | - |
dc.date.available | 2022-12-21T08:03:43Z | - |
dc.date.created | 2022-08-26 | - |
dc.date.issued | 2007-06 | - |
dc.identifier.issn | 1598-2351 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180048 | - |
dc.description.abstract | Since the girders and towers in cable-stayed bridges are subjected to bending moments as well as axial forces, the conventional load rating equation, which considers single force effect only, cannot be used to evaluate the load carrying capacity of cable-stayed bridges. The load rating equations for components in cable-stayed bridges have not currently been established yet. This paper proposes load rating equations for girders and towers in cable-stayed bridges using the interaction equations for beam-column members. Moving load analyses are performed for the cases of maximum axial compressive force, maximum positive moment and maximum negative moment for each component in cable-stayed bridges, and detailed procedures to apply proposed equations are presented. The Dolsan Grand Bridge is used to verify the validity of the proposed equations. The conventional load rating equation overestimates the rating factors of girders and towers in the Dolsan Grand Bridge, whereas proposed equations properly reflect the axial-flexural interaction behavior of girders and towers in cable-stayed bridges. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | KOREAN SOC STEEL CONSTRUCTION-KSSC | - |
dc.title | Evaluation of rating factors for steel cable-stayed bridges using load and resistant factor rating | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Dong Ho | - |
dc.identifier.wosid | 000255406300003 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF STEEL STRUCTURES, v.7, no.2, pp.109 - 118 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF STEEL STRUCTURES | - |
dc.citation.title | INTERNATIONAL JOURNAL OF STEEL STRUCTURES | - |
dc.citation.volume | 7 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 109 | - |
dc.citation.endPage | 118 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001085305 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.subject.keywordAuthor | rating factor | - |
dc.subject.keywordAuthor | beam-column interaction equations | - |
dc.subject.keywordAuthor | cable-stayed bridge | - |
dc.subject.keywordAuthor | Dolsan grand bridge | - |
dc.identifier.url | https://www.kssc.or.kr/wonmun/KSSC_3_2007_7_2_109(C).pdf | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.