A new quantitative Raman measurement scheme using Teflon as a novel intensity correction standard as well as the sample container

Full metadata record
DC Field Value Language
dc.contributor.authorNah, Sanghee-
dc.contributor.authorKim, Donghyuk-
dc.contributor.authorChung, Hoeil-
dc.contributor.authorHan, Sung-Hwan-
dc.contributor.authorYoon, Moon-Young-
dc.date.accessioned2022-12-21T08:26:20Z-
dc.date.available2022-12-21T08:26:20Z-
dc.date.issued2007-05-
dc.identifier.issn0377-0486-
dc.identifier.issn1097-4555-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180171-
dc.description.abstractA novel and reliable quantitative Raman measurement scheme has been proposed for the analyses of ethanol and isopropanol solutions. Teflon tubing was employed as an effective intensity correction standard as well as the sample cell. This allowed for the synchronous collection of the mixed Raman spectrum from the Teflon standard and the sample without any extra optical configuration. A nonoverlapping Teflon band was used as the standard peak to correct the Raman intensity changes resulting from laser power variations. In addition to the use of Teflon tubing,a wide area illumination (WAI) scheme was employed, which made the laser illumination into a circle of 6 mm diameter (area: 28.7 mm(2)), to cover a wide sample area. The WAI scheme improved the reliability of the Raman measurement by significantly increasing the reproducibility of the sampling owing to a decreased sensitivity to sample placement with respect to the focal plane as well as a wider sample coverage area. The resulting Raman spectra were more reproducible and more representative of the correct sample composition. Overall, a superior prediction performance was achieved using the WAI scheme compared to the conventional Raman collection method. The proposed system has great potential for use in the quantitative analysis of diverse liquid samples with good reproducibility.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherJohn Wiley & Sons Inc.-
dc.titleA new quantitative Raman measurement scheme using Teflon as a novel intensity correction standard as well as the sample container-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1002/jrs.1667-
dc.identifier.scopusid2-s2.0-34248202048-
dc.identifier.wosid000246168800001-
dc.identifier.bibliographicCitationJournal of Raman Spectroscopy, v.38, no.5, pp 475 - 482-
dc.citation.titleJournal of Raman Spectroscopy-
dc.citation.volume38-
dc.citation.number5-
dc.citation.startPage475-
dc.citation.endPage482-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSpectroscopy-
dc.relation.journalWebOfScienceCategorySpectroscopy-
dc.subject.keywordPlusMULTIVARIATE CALIBRATION-
dc.subject.keywordPlusSPECTROSCOPY-
dc.subject.keywordPlusSPECTRA-
dc.subject.keywordAuthorRaman spectroscopy-
dc.subject.keywordAuthorTeflon-
dc.subject.keywordAuthorsynchronous standard-
dc.subject.keywordAuthoron-line analysis-
dc.identifier.urlhttps://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jrs.1667-
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE