Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Spatial accuracy of fMRI activation influenced by volume- and surface-based spatial smoothing techniques

Full metadata record
DC Field Value Language
dc.contributor.authorJo, Hang Joon-
dc.contributor.authorLee, Jong Min-
dc.contributor.authorKim, Jae Hun-
dc.contributor.authorShin, Yong Wook-
dc.contributor.authorKim, In Young-
dc.contributor.authorKwon, Jun Soo-
dc.contributor.authorKim, Sun I.-
dc.date.accessioned2022-12-21T09:35:45Z-
dc.date.available2022-12-21T09:35:45Z-
dc.date.issued2007-01-
dc.identifier.issn1053-8119-
dc.identifier.issn1095-9572-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180595-
dc.description.abstractAs improvements in cortical surface modeling allowed accurate cortical topology in brain imaging studies, surface-based methods for the analysis of functional magnetic resonance imaging (fMRI) were introduced to overcome the topological deficiency of commonly used volume-based methods. The difference between the two methods is mainly due to the smoothing techniques applied. For practical applications, the surface-based methods need to quantitatively validate the accuracy of localizing activation. In this study, we evaluated the spatial accuracy of activation detected by the volume- and surface-based methods using simulated blood oxygenation level-dependent (BOLD) signals and MRI phantoms focusing on the influence of their smoothing techniques. T1- and T2-weighted phantoms were acquired from BrainWeb (http://www.bic.mni.mcgill.ca/brainweb/) and used to extract cortical surfaces and to generate echo planar imaging (EPI) data. Simulated BOLD signals as the gold standard of activation in our experiment were applied to the surfaces and projected to the volume space with random noise. Three-dimensional isotropic Gaussian kernel smoothing and two-dimensional heat kernel smoothing were applied to the volume- and surface-based methods. Sensitivity and I-specificity, which are truly and falsely detected activations, and similarity measures, which are spatially and statistically similar for the gold standard and detected activations, were calculated. In the results, the surface-based method showed the sensitivity and similarity scores of about 12% higher than the volume-based method. In conclusion, the surface-based method guarantees better spatial accuracy for the localization of BOLD signal sources within the cortex than the volume-based method.-
dc.format.extent15-
dc.language영어-
dc.language.isoENG-
dc.publisherAcademic Press-
dc.titleSpatial accuracy of fMRI activation influenced by volume- and surface-based spatial smoothing techniques-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.neuroimage.2006.09.047-
dc.identifier.scopusid2-s2.0-33751529162-
dc.identifier.wosid000242901100007-
dc.identifier.bibliographicCitationNeuroImage, v.34, no.2, pp 550 - 564-
dc.citation.titleNeuroImage-
dc.citation.volume34-
dc.citation.number2-
dc.citation.startPage550-
dc.citation.endPage564-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryNeurosciences-
dc.relation.journalWebOfScienceCategoryNeuroimaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusAUTOMATED 3-D EXTRACTION-
dc.subject.keywordPlusDIGITAL BRAIN PHANTOM-
dc.subject.keywordPlusCEREBRAL-CORTEX-
dc.subject.keywordPlusSPIN-ECHO-
dc.subject.keywordPlusTHICKNESS-
dc.subject.keywordPlusMRI-
dc.subject.keywordPlusSCHIZOPHRENIA-
dc.subject.keywordPlusSEQUENCES-
dc.subject.keywordPlusNEURONS-
dc.subject.keywordPlusINNER-
dc.subject.keywordAuthorfunctional magnetic resonance imaging-
dc.subject.keywordAuthoractivation detection-
dc.subject.keywordAuthorsurface-based method-
dc.subject.keywordAuthorphantom study-
dc.subject.keywordAuthorMRI methods/techniques-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1053811906009955?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jong Min photo

Lee, Jong Min
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE