Cited 0 time in
Venous loop mimicking middle cerebral artery bifurcation aneurysm on computed tornographic angiography - case report
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Jae Hoon | - |
| dc.contributor.author | Cheong, Jin Hwan | - |
| dc.contributor.author | Bak, Koang Hum | - |
| dc.contributor.author | Kim, Choong Hyun | - |
| dc.contributor.author | Kim, Jae Min | - |
| dc.date.accessioned | 2022-12-21T09:53:51Z | - |
| dc.date.available | 2022-12-21T09:53:51Z | - |
| dc.date.issued | 2006-11 | - |
| dc.identifier.issn | 0090-3019 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180768 | - |
| dc.description.abstract | Background: CT angiography has been widely used for the detection of cerebral aneurysm. However, there are still limitations despite improving CT angiographic techniques. We describe the unusual case of the detection of a false-positive aneurysm on CT angiography. Case Description: A 64-year-old man presented with a 14-day history of severe headache and nuchal rigidity. Brain CT demonstrated no. subarachnoid hemorrhage, but cerebrospinal fluid appeared xanthochromic in 3 successive tubes after lumbar puncture. Subsequent CT angiography suggested an aneurysm at the bifurcation of the left MCA. However, at operation, prominent sylvian vein superimposed on the bifurcation of the left MCA, and there was no aneurysm. Followup monitoring with conventional angiography at 2 weeks showed no abnormal findings. The patient recovered uneventfully. Conclusion: The case demonstrates that although CT angiography has a reportedly high specificity and sensitivity for the detection of intracranial aneurysm, careful interpretation is required to diagnose intracranial aneurysms. | - |
| dc.format.extent | 3 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Venous loop mimicking middle cerebral artery bifurcation aneurysm on computed tornographic angiography - case report | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1016/j.surneu.2006.02.035 | - |
| dc.identifier.scopusid | 2-s2.0-33750480865 | - |
| dc.identifier.wosid | 000242126000014 | - |
| dc.identifier.bibliographicCitation | Surgical Neurology, v.66, no.5, pp 524 - 526 | - |
| dc.citation.title | Surgical Neurology | - |
| dc.citation.volume | 66 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 524 | - |
| dc.citation.endPage | 526 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Neurosciences & Neurology | - |
| dc.relation.journalResearchArea | Surgery | - |
| dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
| dc.relation.journalWebOfScienceCategory | Surgery | - |
| dc.subject.keywordPlus | TOMOGRAPHIC ANGIOGRAPHY | - |
| dc.subject.keywordPlus | INTRACRANIAL ANEURYSMS | - |
| dc.subject.keywordPlus | CT ANGIOGRAPHY | - |
| dc.subject.keywordPlus | DIAGNOSIS | - |
| dc.subject.keywordPlus | 3D-CTA | - |
| dc.subject.keywordAuthor | CT angiography | - |
| dc.subject.keywordAuthor | venous loop | - |
| dc.subject.keywordAuthor | intracranial aneurysm | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0090301906001807?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
