Cited 0 time in
A novel quantitative validation of the cortical surface reconstruction algorithm using MRI phantom: Issues on local geometric accuracy and cortical thickness
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Junki | - |
| dc.contributor.author | Lee, Jong-Min | - |
| dc.contributor.author | Kim, Jae-Hun | - |
| dc.contributor.author | Kim, In Young | - |
| dc.contributor.author | Evans, Alan C. | - |
| dc.contributor.author | Kim, Sun I. | - |
| dc.date.accessioned | 2022-12-21T10:11:21Z | - |
| dc.date.available | 2022-12-21T10:11:21Z | - |
| dc.date.issued | 2006-10 | - |
| dc.identifier.issn | 0302-9743 | - |
| dc.identifier.issn | 1611-3349 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/180924 | - |
| dc.description.abstract | Cortical surface reconstruction is important for functional brain mapping and morphometric analysis of the brain cortex. Several methods have been developed for the faithful reconstruction of surface models which describe the true cortical surface in both geometry and topology. However there has been no explicit method for the quantitative evaluation of the whole-cortical-surface models. In this study, we present a novel phantom-based evaluation method of the cortical surface reconstruction algorithm and quantitatively validated the local morphometric accuracy of CLASP which is one of the well-established reconstruction methods. The evaluation included local geometrical accuracy and performance of cortical thickness measure. The validation study revealed that there were some underestimations of cortical thickness measure using CLASP in the ventral and sulcal areas of the cortex and overestimations in the gyral areas and inferior temporal lobe. This study could present a generic metric for the quantitative evaluation of cortical surface reconstruction algorithm. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Springer Verlag | - |
| dc.title | A novel quantitative validation of the cortical surface reconstruction algorithm using MRI phantom: Issues on local geometric accuracy and cortical thickness | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.scopusid | 2-s2.0-33750260458 | - |
| dc.identifier.wosid | 000241556300023 | - |
| dc.identifier.bibliographicCitation | Lecture Notes in Computer Science, v.4190, pp 183 - 190 | - |
| dc.citation.title | Lecture Notes in Computer Science | - |
| dc.citation.volume | 4190 | - |
| dc.citation.startPage | 183 | - |
| dc.citation.endPage | 190 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Computer Science | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Theory & Methods | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | AUTOMATED 3-D EXTRACTION | - |
| dc.subject.keywordPlus | CORTEX | - |
| dc.subject.keywordPlus | BRAIN | - |
| dc.subject.keywordPlus | INNER | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.