바닥충격음 측정용 표준충격원과 실충격원의 특성 비교
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 전진용 | - |
| dc.contributor.author | 이평직 | - |
| dc.contributor.author | 정정호 | - |
| dc.contributor.author | 박준홍 | - |
| dc.date.accessioned | 2022-12-21T10:41:53Z | - |
| dc.date.available | 2022-12-21T10:41:53Z | - |
| dc.date.issued | 2006-08 | - |
| dc.identifier.issn | 1598-2785 | - |
| dc.identifier.issn | 2287-5476 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/181117 | - |
| dc.description.abstract | The characteristics of the four standard floor impact sources (impact ball, bang machine, tapping machine, modified tapping machine) and a human impact source (jumping children) were investigated. First, the mechanical impedance of each source were evaluated. Then, the impact force exposure level of each source were measured. The results showed that fundamental frequency and impedance produced by the impact ball are the most similar to those of the human impact source. The frequency characteristics of the impact ball were most similar to those of jumping children. Consequently, the impact ball more accurately reproduces human impact compared to the other standard impact sources. Therefore, the impact ball should be considered as the reliable impactor in evaluating floor impact noise. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국소음진동공학회 | - |
| dc.title | 바닥충격음 측정용 표준충격원과 실충격원의 특성 비교 | - |
| dc.title.alternative | Comparison of Standard Floor Impact Sources with a Human Impact Source | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국소음진동공학회논문집, v.16, no.8, pp 789 - 796 | - |
| dc.citation.title | 한국소음진동공학회논문집 | - |
| dc.citation.volume | 16 | - |
| dc.citation.number | 8 | - |
| dc.citation.startPage | 789 | - |
| dc.citation.endPage | 796 | - |
| dc.identifier.kciid | ART001097056 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Floor Impact Source | - |
| dc.subject.keywordAuthor | 바닥충격원 | - |
| dc.subject.keywordAuthor | Mechanical Impedance | - |
| dc.subject.keywordAuthor | 기계적 임피던스 | - |
| dc.subject.keywordAuthor | Impact Force | - |
| dc.subject.keywordAuthor | 충격력 | - |
| dc.identifier.url | https://www.dbpia.co.kr/pdf/pdfView.do?nodeId=NODE02403910&googleIPSandBox=false&mark=0&useDate=&ipRange=false&accessgl=Y&language=ko_KR&hasTopBanner=true | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.