Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Efficacy of 3-dimensional endorectal ultrasonography compared with conventional ultrasonography and computed tomography in preoperative rectal cancer staging

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jin Cheon-
dc.contributor.authorKim, Hee-Cheol-
dc.contributor.authorYu, Chang S.-
dc.contributor.authorHan, Kyung Ream-
dc.contributor.authorKim, Jung-Ran-
dc.contributor.authorLee, Kanghong-
dc.contributor.authorJang, Se Jin-
dc.contributor.authorLee, Seung-Se-
dc.contributor.authorHa, Hyun Kwon-
dc.date.accessioned2022-12-21T10:57:30Z-
dc.date.available2022-12-21T10:57:30Z-
dc.date.issued2006-07-
dc.identifier.issn0002-9610-
dc.identifier.issn1879-1883-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/181254-
dc.description.abstractBackground: This study was performed to verify reports of the decreased accuracy of endorectal ultrasonography (EUS) in preoperative staging of rectal cancer, and to compare the efficacy of 3-dimensional (3D) EUS with that of 2-dimensional (2D) EUS and computed tomography (CT). Methods: Eighty-six consecutive rectal cancer patients undergoing curative surgery were evaluated by 2D EUS, 3D EUS, and CT scan. Results: The accuracy in T-staging was 78% for 3D EUS, 69% for 2D EUS, and 57% for CT (P < .001-002), whereas the accuracy in evaluating lymph node metastases was 65%, 56%, and 53%, respectively (P < .001-006). Examiner errors were the most frequent cause of misinterpretation, occurring in 47% of 2D EUS examinations and in 65% of 3D EUS examinations. By eliminating examiner errors, the accuracy rates in T-staging and lymph node evaluation could be improved to 88% and 76%, respectively, for 2D EUS, and to 91% and 90%, respectively, for 3D EUS. Conical protrusions along the deep tumor border on 3D images were correlated closely with infiltration grade, advanced T-stage, and lymph node metastasis. Conclusions: We found that 3D EUS showed greater accuracy than 2D EUS or CT in rectal cancer staging and lymph node metastases. Concrete 3D images based on tumor,biology appear to provide more accurate information on tumor progression.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleEfficacy of 3-dimensional endorectal ultrasonography compared with conventional ultrasonography and computed tomography in preoperative rectal cancer staging-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.amjsurg.2006.01.054-
dc.identifier.scopusid2-s2.0-33744942879-
dc.identifier.wosid000238549500018-
dc.identifier.bibliographicCitationAmerican Journal of Surgery, v.192, no.1, pp 89 - 97-
dc.citation.titleAmerican Journal of Surgery-
dc.citation.volume192-
dc.citation.number1-
dc.citation.startPage89-
dc.citation.endPage97-
dc.type.docTypeEditorial Material-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusENDOLUMINAL ULTRASOUND-
dc.subject.keywordPlusTRANSRECTAL ULTRASOUND-
dc.subject.keywordPlusCARCINOMA-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordPlusTUMORS-
dc.subject.keywordPlusSONOGRAPHY-
dc.subject.keywordPlusEXCISION-
dc.subject.keywordPlusINVASION-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordAuthorrectal cancer-
dc.subject.keywordAuthorstaging-
dc.subject.keywordAuthortwo-dimensional-
dc.subject.keywordAuthorthree-dimensional-
dc.subject.keywordAuthorultrasonography-
dc.subject.keywordAuthorcomputed tomography-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0002961006002339?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE