Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Moment combined partial least squares (MC-PLS) as an improved quantitative calibration method: application to the analyses of petroleum and petrochemical products

Full metadata record
DC Field Value Language
dc.contributor.authorChung, Hoeil-
dc.contributor.authorCho, Soohwa-
dc.contributor.authorToyoda, Yukihiro-
dc.contributor.authorNakano, Kazushi-
dc.contributor.authorMaeda, Manabu-
dc.date.accessioned2022-12-21T11:54:18Z-
dc.date.available2022-12-21T11:54:18Z-
dc.date.issued2006-03-
dc.identifier.issn0003-2654-
dc.identifier.issn1364-5528-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/181708-
dc.description.abstractA new quantitative calibration algorithm, called "Moment Combined Partial Least Squares ( MC-PLS)'', which combines the moment of spectrum and conventional PLS was proposed. Its calibration performance was evaluated for the analyses of three import petroleum and petrochemical products: gasoline, naphtha and polyol samples. The selected properties for these products included the research octane number ( RON) and Reid vapor pressure ( RVP) for gasoline, the distillation temperature at 10% ( D 10%) for naphtha and the hydroxyl ( OH) number for polyol. The major concept presented here used the moment to find the closest spectrum of a sample in a given dataset, and generate the difference spectrum and the corresponding difference in the property. These difference spectra and property differences were then used for PLS calibration. The moment has been employed in spectroscopic fields as a simple and effective "spectral feature characteristic'' using just a few scalar values ( moments). MC-PLS showed improved prediction performance over PLS for each case. In MC-PLS, the difference spectra generated using the moments were used as explained; therefore, additional detail in spectral variations can be utilized for calibrations. Additionally, the difference in the property was employed as reference data, so that its variation range was smaller when compared with that of the original property. Consequently, the MC-PLS performance could be better since the feature-enhanced spectra were used to model a narrower range of property variations. In the case of the D 10% prediction for naphtha, a non-linear prediction pattern that occurred in conventional PLS was effectively corrected using the MC-PLS method.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherRoyal Society of Chemistry-
dc.titleMoment combined partial least squares (MC-PLS) as an improved quantitative calibration method: application to the analyses of petroleum and petrochemical products-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1039/b515761g-
dc.identifier.scopusid2-s2.0-33745713820-
dc.identifier.wosid000236970200009-
dc.identifier.bibliographicCitationAnalyst, v.131, no.5, pp 684 - 691-
dc.citation.titleAnalyst-
dc.citation.volume131-
dc.citation.number5-
dc.citation.startPage684-
dc.citation.endPage691-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusNEAR-INFRARED SPECTROSCOPY-
dc.subject.keywordPlusCOMPOSITIONAL ANALYSIS-
dc.subject.keywordPlusPREDICTION-
dc.subject.keywordPlusGASOLINE-
dc.subject.keywordPlusCLASSIFICATION-
dc.subject.keywordPlusNAPHTHA-
dc.subject.keywordPlusNUMBER-
dc.identifier.urlhttps://pubs.rsc.org/en/content/articlelanding/2006/AN/b515761g-
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE