| dc.description.abstract | In this paper, we propose a subject-independent regression model to estimate systolic blood pressures (SBP) conveniently and continuously. There have been several researches on estimating SBP with pulse transit time (PTT) and they showed promising results. However, previous studies used only PTT as the estimation parameter, and their models were generated with just one person’s PTT data which is not applicable to estimating other person’s SBP. Therefore, we collected several additional biometric parameters with 202 healthy subjects. After statistical analysis of measured biometric parameters with SBP, we chose final estimating parameters including PTT to generate a multiple linear regression model for estimating SBP. Comparing the results of our study with approvable standards of automated sphygmomanometers developed by Association for the Advancement of Medical Instrumentation and approved by American National Standards Institute (ANSI/AAMI) indicates that our proposed method for continuously blood pressures monitoring gives an acceptable error. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | 대한의용생체공학회 | - |
| dc.title | A Study on the Estimation of Continuous Blood Pressure using PTT and Biometric Parameters | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 황환식 | - |
| dc.contributor.affiliatedAuthor | 박훈기 | - |
| dc.contributor.affiliatedAuthor | 김인영 | - |
| dc.identifier.bibliographicCitation | 의공학회지, v.27, no.1, pp.1 - 5 | - |
| dc.relation.isPartOf | 의공학회지 | - |
| dc.citation.title | 의공학회지 | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 5 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART001115489 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | blood pressure | - |
| dc.subject.keywordAuthor | continuous | - |
| dc.subject.keywordAuthor | pulse transit time | - |
| dc.subject.keywordAuthor | noninvasive | - |
| dc.subject.keywordAuthor | cuffless | - |
| dc.identifier.url | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001115489 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.