Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Study on the Estimation of Continuous Blood Pressure using PTT and Biometric Parameters

Full metadata record
DC Field Value Language
dc.contributor.author박은경-
dc.contributor.author조백환-
dc.contributor.author박상해-
dc.contributor.author이종연-
dc.contributor.author황환식-
dc.contributor.author박훈기-
dc.contributor.author이종실-
dc.contributor.author김인영-
dc.contributor.author김선일-
dc.date.accessioned2022-12-21T11:59:16Z-
dc.date.available2022-12-21T11:59:16Z-
dc.date.created2022-09-19-
dc.date.issued2006-02-
dc.identifier.issn1229-0807-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/181762-
dc.description.abstractIn this paper, we propose a subject-independent regression model to estimate systolic blood pressures (SBP) conveniently and continuously. There have been several researches on estimating SBP with pulse transit time (PTT) and they showed promising results. However, previous studies used only PTT as the estimation parameter, and their models were generated with just one person’s PTT data which is not applicable to estimating other person’s SBP. Therefore, we collected several additional biometric parameters with 202 healthy subjects. After statistical analysis of measured biometric parameters with SBP, we chose final estimating parameters including PTT to generate a multiple linear regression model for estimating SBP. Comparing the results of our study with approvable standards of automated sphygmomanometers developed by Association for the Advancement of Medical Instrumentation and approved by American National Standards Institute (ANSI/AAMI) indicates that our proposed method for continuously blood pressures monitoring gives an acceptable error.-
dc.language영어-
dc.language.isoen-
dc.publisher대한의용생체공학회-
dc.titleA Study on the Estimation of Continuous Blood Pressure using PTT and Biometric Parameters-
dc.typeArticle-
dc.contributor.affiliatedAuthor황환식-
dc.contributor.affiliatedAuthor박훈기-
dc.contributor.affiliatedAuthor김인영-
dc.identifier.bibliographicCitation의공학회지, v.27, no.1, pp.1 - 5-
dc.relation.isPartOf의공학회지-
dc.citation.title의공학회지-
dc.citation.volume27-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage5-
dc.type.rimsART-
dc.identifier.kciidART001115489-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorblood pressure-
dc.subject.keywordAuthorcontinuous-
dc.subject.keywordAuthorpulse transit time-
dc.subject.keywordAuthornoninvasive-
dc.subject.keywordAuthorcuffless-
dc.identifier.urlhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001115489-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles
서울 의과대학 > 서울 가정의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Hoon ki photo

Park, Hoon ki
서울 의과대학 (DEPARTMENT OF FAMILY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE