Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

An Investigation of Body Size Impact on Organ Doses for Neutron External Exposures Using the MRCP-based Phantom Library

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Haegin-
dc.contributor.authorChoi, Ji Won-
dc.contributor.authorLee, Yumi-
dc.contributor.authorLee, Soo Min-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorChoi, Hyun Joon-
dc.contributor.authorYeom, Yeon Soo-
dc.date.accessioned2023-05-03T09:58:38Z-
dc.date.available2023-05-03T09:58:38Z-
dc.date.created2023-03-08-
dc.date.issued2023-04-
dc.identifier.issn0017-9078-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/184986-
dc.description.abstractIn a recent study, a comprehensive library composed of 212 phantoms with different body sizes was established by deforming the adult male and female mesh-type reference computational phantoms (MRCPs) of ICRP Publication 145 and the next-generation ICRP reference phantoms over the current voxel-type reference phantoms of ICRP Publication 110. In this study, as an application of the MRCP-based phantom library, we investigated dosimetric impacts due to the different body sizes for neutron external exposures. A comprehensive dataset of organ/tissue dose coefficients (DCs) for idealized external neutron beams with four phantoms for each sex representatively selected from the phantom library were produced by performing Monte Carlo simulations using the Geant4 code. The body size-dependent DCs produced in this study were systematically analyzed, observing that the variation of the body weights overall played a more important role in organ/tissue dose calculations than the variation of the body heights. We also observed that the reference body-size DCs based on the MRCPs indeed significantly under- or overestimated the DCs produced using the phantoms, especially for those much heavier (male: 175 cm and 140 kg; female: 165 cm and 140 kg) than the reference body sizes (male: 176 cm and 73 kg; female: 163 cm and 60 kg) by up to 1.6 or 3.3 times, respectively. We believe that the use of the body size-dependent DCs, together with the reference body-size DCs, should be beneficial for more reliable organ/tissue dose estimates of individuals considering their body sizes rather than the most common conventional approach, i.e., the sole use of the reference body size DCs.-
dc.language영어-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.titleAn Investigation of Body Size Impact on Organ Doses for Neutron External Exposures Using the MRCP-based Phantom Library-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1097/HP.0000000000001672-
dc.identifier.scopusid2-s2.0-85148679046-
dc.identifier.wosid000937057800007-
dc.identifier.bibliographicCitationHEALTH PHYSICS, v.124, no.4, pp.316 - 325-
dc.relation.isPartOfHEALTH PHYSICS-
dc.citation.titleHEALTH PHYSICS-
dc.citation.volume124-
dc.citation.number4-
dc.citation.startPage316-
dc.citation.endPage325-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusbody size-
dc.subject.keywordPlusbody weight-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusimaging phantom-
dc.subject.keywordPlusmagnetic resonance cholangiopancreatography-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusMonte Carlo method-
dc.subject.keywordPlusneutron-
dc.subject.keywordPlusradiation dose-
dc.subject.keywordPlusradiometry-
dc.subject.keywordAuthordose, external-
dc.subject.keywordAuthordose, organ-
dc.subject.keywordAuthorMonte Carlo-
dc.subject.keywordAuthorphantom, mathematical-
dc.identifier.urlhttps://journals.lww.com/health-physics/Fulltext/2023/04000/An_Investigation_of_Body_Size_Impact_on_Organ.7.aspx-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE