Cited 0 time in
Detection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lim, Hyunyoung | - |
| dc.contributor.author | Kim, Eugene | - |
| dc.contributor.author | Kim, Soo Yeon | - |
| dc.contributor.author | Kim, Ji-Yoon | - |
| dc.contributor.author | Jung, Yundo | - |
| dc.contributor.author | Lee, Tagkeun | - |
| dc.contributor.author | Kim, Nayeon | - |
| dc.contributor.author | Tae, Kyung | - |
| dc.date.accessioned | 2023-05-03T11:21:40Z | - |
| dc.date.available | 2023-05-03T11:21:40Z | - |
| dc.date.issued | 2023-02 | - |
| dc.identifier.issn | 1043-3074 | - |
| dc.identifier.issn | 1097-0347 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/185229 | - |
| dc.description.abstract | Background During transoral robot-assisted thyroidectomy, there is a risk of increasing intracranial pressure because the site of CO2 insufflation is narrow and close to the brain. Methods We analyzed the pre- to post-CO2 neck insufflation change in the optic nerve sheath diameter during transoral robot-assisted thyroidectomy. Changes in vital-signs, airway pressure, and arterial carbon dioxide pressure were analyzed along with postoperative complications. Results Among the 30 participants, the post-CO2 inflation mean optic nerve sheath diameter (5.64 +/- 0.54 mm) was higher than the pre-induction diameter (4.81 +/- 0.37 mm) with a mean difference of 0.83 (95% CI, 0.69-0.97; p < 0.001), but returned to baseline after CO2 deflation in most cases. One participant had sustained increased optic nerve sheath diameter (6.35 mm) associated with severe new-onset postoperative headache. Conclusion Transient elevation in the intracranial pressure during low-pressure CO2 neck insufflation in the transoral robot-assisted thyroidectomy did not appear to adversely affect patients. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | John Wiley & Sons Inc. | - |
| dc.title | Detection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1002/hed.27234 | - |
| dc.identifier.scopusid | 2-s2.0-85141509619 | - |
| dc.identifier.wosid | 000879095100001 | - |
| dc.identifier.bibliographicCitation | Head and Neck, v.45, no.2, pp 329 - 336 | - |
| dc.citation.title | Head and Neck | - |
| dc.citation.volume | 45 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 329 | - |
| dc.citation.endPage | 336 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Otorhinolaryngology | - |
| dc.relation.journalResearchArea | Surgery | - |
| dc.relation.journalWebOfScienceCategory | Otorhinolaryngology | - |
| dc.relation.journalWebOfScienceCategory | Surgery | - |
| dc.subject.keywordPlus | SURGERY | - |
| dc.subject.keywordPlus | ULTRASONOGRAPHY | - |
| dc.subject.keywordAuthor | CO2 insufflation | - |
| dc.subject.keywordAuthor | intracranial pressure | - |
| dc.subject.keywordAuthor | optic nerve sheath diameter | - |
| dc.subject.keywordAuthor | trans-oral robotic thyroidectomy | - |
| dc.identifier.url | https://onlinelibrary.wiley.com/doi/10.1002/hed.27234 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.