Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Detection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement

Full metadata record
DC Field Value Language
dc.contributor.authorLim, Hyunyoung-
dc.contributor.authorKim, Eugene-
dc.contributor.authorKim, Soo Yeon-
dc.contributor.authorKim, Ji-Yoon-
dc.contributor.authorJung, Yundo-
dc.contributor.authorLee, Tagkeun-
dc.contributor.authorKim, Nayeon-
dc.contributor.authorTae, Kyung-
dc.date.accessioned2023-05-03T11:21:40Z-
dc.date.available2023-05-03T11:21:40Z-
dc.date.created2022-12-07-
dc.date.issued2023-02-
dc.identifier.issn1043-3074-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/185229-
dc.description.abstractBackground During transoral robot-assisted thyroidectomy, there is a risk of increasing intracranial pressure because the site of CO2 insufflation is narrow and close to the brain. Methods We analyzed the pre- to post-CO2 neck insufflation change in the optic nerve sheath diameter during transoral robot-assisted thyroidectomy. Changes in vital-signs, airway pressure, and arterial carbon dioxide pressure were analyzed along with postoperative complications. Results Among the 30 participants, the post-CO2 inflation mean optic nerve sheath diameter (5.64 +/- 0.54 mm) was higher than the pre-induction diameter (4.81 +/- 0.37 mm) with a mean difference of 0.83 (95% CI, 0.69-0.97; p < 0.001), but returned to baseline after CO2 deflation in most cases. One participant had sustained increased optic nerve sheath diameter (6.35 mm) associated with severe new-onset postoperative headache. Conclusion Transient elevation in the intracranial pressure during low-pressure CO2 neck insufflation in the transoral robot-assisted thyroidectomy did not appear to adversely affect patients.-
dc.language영어-
dc.language.isoen-
dc.publisherWILEY-
dc.titleDetection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement-
dc.typeArticle-
dc.contributor.affiliatedAuthorLim, Hyunyoung-
dc.contributor.affiliatedAuthorKim, Eugene-
dc.contributor.affiliatedAuthorTae, Kyung-
dc.identifier.doi10.1002/hed.27234-
dc.identifier.scopusid2-s2.0-85141509619-
dc.identifier.wosid000879095100001-
dc.identifier.bibliographicCitationHEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, v.45, no.2, pp.329 - 336-
dc.relation.isPartOfHEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK-
dc.citation.titleHEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK-
dc.citation.volume45-
dc.citation.number2-
dc.citation.startPage329-
dc.citation.endPage336-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOtorhinolaryngology-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOtorhinolaryngology-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusULTRASONOGRAPHY-
dc.subject.keywordAuthorCO2 insufflation-
dc.subject.keywordAuthorintracranial pressure-
dc.subject.keywordAuthoroptic nerve sheath diameter-
dc.subject.keywordAuthortrans-oral robotic thyroidectomy-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/10.1002/hed.27234-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 이비인후과학교실 > 1. Journal Articles
서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Hyun young photo

Lim, Hyun young
COLLEGE OF MEDICINE (DEPARTMENT OF ANESTHESIA AND MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE