Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Novel hybrid visual stimuli incorporating periodic motions into conventional flickering or pattern-reversal visual stimuli for steady-state visual evoked potential-based brain-computer interfaces

Full metadata record
DC Field Value Language
dc.contributor.authorKwon, Jinuk-
dc.contributor.author황지훈-
dc.contributor.authorNam, Hyerin-
dc.contributor.authorIm, Chang Hwan-
dc.date.accessioned2023-05-03T11:28:10Z-
dc.date.available2023-05-03T11:28:10Z-
dc.date.issued2022-09-
dc.identifier.issn1662-5196-
dc.identifier.issn1662-5196-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/185248-
dc.description.abstractIn this study, we proposed a new type of hybrid visual stimuli for steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs), which incorporate various periodic motions into conventional flickering stimuli (FS) or pattern reversal stimuli (PRS). Furthermore, we investigated optimal periodic motions for each FS and PRS to enhance the performance of SSVEP-based BCIs. Periodic motions were implemented by changing the size of the stimulus according to four different temporal functions denoted by none, square, triangular, and sine, yielding a total of eight hybrid visual stimuli. Additionally, we developed the extended version of filter bank canonical correlation analysis (FBCCA), which is a state-of-the-art training-free classification algorithm for SSVEP-based BCIs, to enhance the classification accuracy for PRS-based hybrid visual stimuli. Twenty healthy individuals participated in the SSVEP-based BCI experiment to discriminate four visual stimuli with different frequencies. An average classification accuracy and information transfer rate (ITR) were evaluated to compare the performances of SSVEP-based BCIs for different hybrid visual stimuli. Additionally, the user's visual fatigue for each of the hybrid visual stimuli was also evaluated. As the result, for FS, the highest performances were reported when the periodic motion of the sine waveform was incorporated for all window sizes except for 3 s. For PRS, the periodic motion of the square waveform showed the highest classification accuracies for all tested window sizes. A significant statistical difference in the performance between the two best stimuli was not observed. The averaged fatigue scores were reported to be 5.3 ± 2.05 and 4.05 ± 1.28 for FS with sine-wave periodic motion and PRS with square-wave periodic motion, respectively. Consequently, our results demonstrated that FS with sine-wave periodic motion and PRS with square-wave periodic motion could effectively improve the BCI performances compared to conventional FS and PRS. In addition, thanks to its low visual fatigue, PRS with square-wave periodic motion can be regarded as the most appropriate visual stimulus for the long-term use of SSVEP-based BCIs, particularly for window sizes equal to or larger than 2 s.-
dc.format.extent13-
dc.language영어-
dc.language.isoENG-
dc.publisherFrontiers Media S.A.-
dc.titleNovel hybrid visual stimuli incorporating periodic motions into conventional flickering or pattern-reversal visual stimuli for steady-state visual evoked potential-based brain-computer interfaces-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3389/fninf.2022.997068-
dc.identifier.scopusid2-s2.0-85140068427-
dc.identifier.wosid000891742000001-
dc.identifier.bibliographicCitationFrontiers in Neuroinformatics, v.16, pp 1 - 13-
dc.citation.titleFrontiers in Neuroinformatics-
dc.citation.volume16-
dc.citation.startPage1-
dc.citation.endPage13-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMathematical & Computational Biology-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalWebOfScienceCategoryMathematical & Computational Biology-
dc.relation.journalWebOfScienceCategoryNeurosciences-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusamblyopia-
dc.subject.keywordPlusArticle-
dc.subject.keywordPlusauditory stimulation-
dc.subject.keywordPlusclinical article-
dc.subject.keywordPluscontrolled study-
dc.subject.keywordPluscorrelation analysis-
dc.subject.keywordPlusevoked brain stem auditory response-
dc.subject.keywordPluseye movement-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlusFourier transform-
dc.subject.keywordPlushuman-
dc.subject.keywordPlushuman experiment-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusnormal human-
dc.subject.keywordPlusvisual evoked potential-
dc.subject.keywordPlusvisual stimulation-
dc.subject.keywordPluswaveform-
dc.subject.keywordPlusyoung adult-
dc.subject.keywordAuthorbrain-computer interfaces (BCIs)-
dc.subject.keywordAuthorsteady-state visual evoked potential (SSVEP)-
dc.subject.keywordAuthorsteady-state motion visual evoked potential (SSMVEP)-
dc.subject.keywordAuthorhybrid visual stimulus-
dc.subject.keywordAuthorperiodic motion-
dc.identifier.urlhttps://www.frontiersin.org/articles/10.3389/fninf.2022.997068/full-
Files in This Item
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Im, Chang Hwan photo

Im, Chang Hwan
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE