Miniaturized Four-port MIMO Implantable Antenna for High Data-Rate Wireless Capsule Endoscopy Applications
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Shah, Syed Manaf Ali | - |
| dc.contributor.author | 자다 무하마드 | - |
| dc.contributor.author | Nasir, Jamal | - |
| dc.contributor.author | Owais, Owais | - |
| dc.contributor.author | Iqbal, Amjad | - |
| dc.contributor.author | Yoo, Hyoungsuk | - |
| dc.date.accessioned | 2023-06-01T06:44:08Z | - |
| dc.date.available | 2023-06-01T06:44:08Z | - |
| dc.date.issued | 2023-04 | - |
| dc.identifier.issn | 0018-926X | - |
| dc.identifier.issn | 1558-2221 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/185745 | - |
| dc.description.abstract | This study proposes a miniaturized four-port multiple-input-multiple-output (MIMO) implantable antenna for wireless capsule endoscopy (WCE). The proposed MIMO implantable antenna operates in the 2.45 GHz industrial, scientific, and medical (ISM) band, has a compact size of 6.2 × 5.2 × 0.127 mm3, and comprises four meandered resonators sharing a common slotless ground plane with an acceptable bandwidth (14.2%) and low mutual coupling. These features help the antenna achieve high data rates and countering multipath distortions, as confirmed using MIMO channel parameters. The calculated link budget analysis of the proposed antenna suggests that seamless high-rate (78 Mbps) information transmission can be efficiently achieved over a distance of up to 10 m (when placed in the large intestine). The proposed MIMO implantable antenna was optimized by placing it inside a capsule comprising sensors, batteries, and electronic components, and was subsequently fabricated. The simulated (S-parameters, gain, and radiation patterns) and measured (in the minced pork) results were in close agreement with a measured bandwidth of 350 MHz and a peak measured gain of -20.1 dBi. To ensure patient safety, the specific absorption rate (SAR) was evaluated for all four ports in different environments (stomach and small and large intestines), and satisfactory results were obtained. MIMO performance parameters, such as the envelope correlation coefficient (ECC), diversity gain (DG), and channel capacity (CC) were also evaluated and acceptable values were noted. To the best of our knowledge, this is the most compact 4-element implantable MIMO antenna designed so far for biomedical applications. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers | - |
| dc.title | Miniaturized Four-port MIMO Implantable Antenna for High Data-Rate Wireless Capsule Endoscopy Applications | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TAP.2023.3243984 | - |
| dc.identifier.scopusid | 2-s2.0-85149377730 | - |
| dc.identifier.wosid | 000970764800001 | - |
| dc.identifier.bibliographicCitation | IEEE Transactions on Antennas and Propagation, v.71, no.4, pp 3123 - 3133 | - |
| dc.citation.title | IEEE Transactions on Antennas and Propagation | - |
| dc.citation.volume | 71 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 3123 | - |
| dc.citation.endPage | 3133 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Telecommunications | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Telecommunications | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordPlus | BANDS | - |
| dc.subject.keywordAuthor | Channel capacity (CC) | - |
| dc.subject.keywordAuthor | link budget | - |
| dc.subject.keywordAuthor | multiple-input multiple-output (MIMO) | - |
| dc.subject.keywordAuthor | mutual coupling | - |
| dc.subject.keywordAuthor | wireless capsule endoscopy (WCE) | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/10045709 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.