Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

TET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-Mesh- Phantom to DICOM-RT Dataset

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Se Hyung-
dc.contributor.authorCheon, Bo-Wi-
dc.contributor.authorMin, Chul Hee-
dc.contributor.authorHan, Haegin-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorHan, Min Cheo-
dc.contributor.authorKim, Seonghoon-
dc.date.accessioned2023-06-01T07:15:07Z-
dc.date.available2023-06-01T07:15:07Z-
dc.date.created2023-05-03-
dc.date.issued2022-12-
dc.identifier.issn2508-4445-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/185975-
dc.description.abstractRecently, tetrahedral phantoms have been newly adopted as international standard mesh-type reference computational phantoms (MRCPs) by the International Commission on Radiological Protection, and a program has been developed to convert them to computational tomography images and DICOM-RT structure files for application of radiotherapy. Through this program, the use of the tetrahedral standard phantom has become available in clinical practice, but utilization has been difficult due to various library dependencies requiring a lot of time and effort for installation. To overcome this limitation, in this study a newly developed TET2DICOM-GUI, a TET2DICOM program based on a graphical user interface (GUI), was programmed using only the MATLAB language so that it can be used without additional library installation and configuration. The program runs in the same order as TET2DICOM and has been optimized to run on a personal computer in a GUI environment. A tetrahedron-based male international standard human phantom, MRCP-AM, was used to evaluate TET2DICOM-GUI. Conversion into a DICOM-RT dataset applicable in clinical practice in about one hour with a personal computer as a basis was confirmed. Also, the generated DICOM-RT dataset was confirmed to be effectively implemented in the radiotherapy planning system. The program developed in this study is expected to replace actual patient data in future studies.-
dc.language영어-
dc.language.isoen-
dc.publisher한국의학물리학회-
dc.titleTET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-Mesh- Phantom to DICOM-RT Dataset-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.14316/pmp.2022.33.4.172-
dc.identifier.bibliographicCitation의학물리, v.33, no.4, pp.172 - 179-
dc.relation.isPartOf의학물리-
dc.citation.title의학물리-
dc.citation.volume33-
dc.citation.number4-
dc.citation.startPage172-
dc.citation.endPage179-
dc.type.rimsART-
dc.identifier.kciidART002919953-
dc.description.journalClass2-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorTetrahedral-mesh phantom-
dc.subject.keywordAuthorDICOM-
dc.subject.keywordAuthorVoxelization-
dc.subject.keywordAuthorComputational tomography-
dc.subject.keywordAuthorRT structure-
dc.identifier.urlhttps://www.progmedphys.org/journal/view.html?doi=10.14316/pmp.2022.33.4.172-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE