Cited 0 time in
Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | An, Seohyeon | - |
| dc.contributor.author | Park, Sang-il | - |
| dc.contributor.author | Jeong, Seonghoon | - |
| dc.contributor.author | Min, Soonki | - |
| dc.contributor.author | Kim, Tae Jeong | - |
| dc.contributor.author | Shin, Dongho | - |
| dc.contributor.author | Lim, Youngkyung | - |
| dc.contributor.author | Jeong, Jong Hwi | - |
| dc.contributor.author | Kim, Haksoo | - |
| dc.contributor.author | Lee, Se Byeong | - |
| dc.date.accessioned | 2023-06-01T07:15:42Z | - |
| dc.date.available | 2023-06-01T07:15:42Z | - |
| dc.date.issued | 2022-12 | - |
| dc.identifier.issn | 2508-4445 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/185981 | - |
| dc.description.abstract | Purpose: Proton therapy has different relative biological effectiveness (RBE) compared with X-ray treatment, which is the standard in radiation therapy, and the fixed RBE value of 1.1 is widely used. However, RBE depends on a charged particle’s linear energy transfer (LET); therefore, measuring LET is important. We have developed a LET measurement method using the inefficiency characteristic of an EBT3 film on a proton beam’s Bragg peak (BP) region. Methods: A Gafchromic EBT3 film was used to measure the proton beam LET. It measured the dose at a 10-cm pristine BP proton beam in water to determine the quenching factor of the EBT3 film as a reference beam condition. Monte Carlo (MC) calculations of dose-averaged LET (LETd) were used to determine the quenching factor and validation. The dose-averaged LETs at the 12-, 16-, and 20-cm pristine BP proton beam in water were calculated with the quenching factor. Results: Using the passive scattering proton beam nozzle of the National Cancer Center in Korea, the LETd was measured for each beam range. The quenching factor was determined to be 26.15 with 0.3% uncertainty under the reference beam condition. The dose-averaged LETs were measured for each test beam condition. Conclusions: We developed a method for measuring the proton beam LET using an EBT3 film. This study showed that the magnitude of the quenching effect can be estimated using only one beam range, and the quenching factor determined under the reference condition can be applied to any therapeutic proton beam range. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국의학물리학회 | - |
| dc.title | Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.14316/pmp.2022.33.4.80 | - |
| dc.identifier.bibliographicCitation | PROGRESS in MEDICAL PHYSICS, v.33, no.4, pp 80 - 87 | - |
| dc.citation.title | PROGRESS in MEDICAL PHYSICS | - |
| dc.citation.volume | 33 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 80 | - |
| dc.citation.endPage | 87 | - |
| dc.identifier.kciid | ART002919614 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Proton therapy | - |
| dc.subject.keywordAuthor | Linear energy transfer | - |
| dc.subject.keywordAuthor | Film dosimetry | - |
| dc.subject.keywordAuthor | EBT3 | - |
| dc.identifier.url | https://www.progmedphys.org/journal/view.html?doi=10.14316/pmp.2022.33.4.80 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.