Cited 0 time in
New algorithm to estimate proton beam range for multi-slit prompt-gamma camera
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ku, Youngmo | - |
| dc.contributor.author | Jung, Jaerin | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.date.accessioned | 2023-07-05T03:54:07Z | - |
| dc.date.available | 2023-07-05T03:54:07Z | - |
| dc.date.created | 2022-06-03 | - |
| dc.date.issued | 2022-09 | - |
| dc.identifier.issn | 1738-5733 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/186193 | - |
| dc.description.abstract | The prompt gamma imaging (PGI) technique is considered as one of the most promising approaches to estimate the range of proton beam in the patient and unlock the full potential of proton therapy. In the PGI technique, a dedicated algorithm is required to estimate the range of the proton beam from the prompt gamma (PG) distribution acquired by a PGI system. In the present study, a new range estimation algorithm was developed for a multi-slit prompt-gamma camera, one of PGI systems, to estimate the range of proton beam with high accuracy. The performance of the developed algorithm was evaluated by Monte Carlo simulations for various beam/phantom combinations. Our results generally show that the developed algorithm is very robust, showing very high accuracy and precision for all the cases considered in the present study. The range estimation accuracy of the developed algorithm was 0.5–1.7 mm, which is approximately 1% of beam range, for 1 × 109 protons. Even for the typical number of protons for a spot (1 × 108), the range estimation accuracy of the developed algorithm was 2.1–4.6 mm and smaller than the range uncertainties and typical safety margin, while that of the existing algorithm was 2.5–9.6 mm. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | Korean Nuclear Society | - |
| dc.title | New algorithm to estimate proton beam range for multi-slit prompt-gamma camera | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Kim, Chan Hyeong | - |
| dc.identifier.doi | 10.1016/j.net.2022.04.019 | - |
| dc.identifier.scopusid | 2-s2.0-85130369595 | - |
| dc.identifier.wosid | 000862947300008 | - |
| dc.identifier.bibliographicCitation | Nuclear Engineering and Technology, v.54, no.9, pp.3422 - 3428 | - |
| dc.relation.isPartOf | Nuclear Engineering and Technology | - |
| dc.citation.title | Nuclear Engineering and Technology | - |
| dc.citation.volume | 54 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 3422 | - |
| dc.citation.endPage | 3428 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002867071 | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | VERIFICATION | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.subject.keywordAuthor | Multi-slit prompt-gamma camera | - |
| dc.subject.keywordAuthor | Prompt gamma imaging | - |
| dc.subject.keywordAuthor | Proton therapy | - |
| dc.subject.keywordAuthor | Range estimation | - |
| dc.subject.keywordAuthor | Range uncertainty | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1738573322002406?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.