Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Association of Longitudinal Mammographic Breast Density Changes with Subsequent Breast Cancer Risk

Authors
Tran, Thi Xuan MaiKim, SoyeounSong, HuiyeonLee, EunhyePark, Boyoung
Issue Date
Feb-2023
Publisher
RADIOLOGICAL SOC NORTH AMERICA (RSNA)
Citation
RADIOLOGY, v.306, no.2, pp.1 - 10
Indexed
SCIE
SCOPUS
Journal Title
RADIOLOGY
Volume
306
Number
2
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/187253
DOI
10.1148/radiol.220291
ISSN
0033-8419
Abstract
Background: Although Breast Imaging Reporting and Data System (BI-RADS) density classification has been used to assess future breast cancer risk, its reliability and validity are still debated in literature. Purpose: To determine the association between overall longitudinal changes in mammographic breast density and breast cancer risk stratified by menopausal status. Materials and Methods: In a retrospective cohort study using the Korean National Health Insurance Service database, women aged at least 40 years without a history of cancer who underwent three consecutive biennial mammographic screenings in 2009-2014 were followed up through December 2020. Participants were divided according to baseline breast density: fatty (BI-RADS categories a, b) versus dense (BI-RADS categories c, d) and then into subgroups on the basis of changes from the first to second and from second to third screenings. Women without change in breast density were used as the reference group. Main outcomes were incident breast cancer events, both invasive breast cancer and ductal carcinoma in situ. Cox proportion hazard regression was used to calculate the hazard ratio (HR) with adjustment for other covariables. Results: Among 2 253 963 women (mean age, 59 years ± 9) there were 22 439 detected breast cancers. Premenopausal women with fatty breasts at the first screening had a higher risk of breast cancer as density increased in the second and third screenings (fatty-to-dense HR, 1.45 [95% CI: 1.27, 1.65]; dense-to-fatty HR, 1.53 [95% CI: 1.34, 1.74]; dense-to-dense HR, 1.93 [95% CI: 1.75, 2.13]). In premenopausal women with dense breasts at baseline, those in whom density continuously decreased had a 0.62-fold lower risk (95% CI: 0.56, 0.69). Similar results were observed in postmenopausal women, remaining significant after adjustment for baseline breast density or changes in body mass index (fatty-to-dense HR, 1.50 [95% CI: 1.39, 1.62]; dense-to-fatty HR, 1.42 [95% CI: 1.31, 1.53]; dense-to-dense HR, 1.62 [95% CI: 1.51, 1.75]). Conclusion: In both premenopausal and postmenopausal women undergoing three consecutive biennial mammographic screenings, a consecutive increase in breast density augmented the future breast cancer risk whereas a continuous decrease was associated with a lower risk.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 예방의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Bo Young photo

Park, Bo Young
COLLEGE OF MEDICINE (DEPARTMENT OF PREVENTIVE MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE