Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Palatal Electrotactile Display Outperforms Visual Display in Tongue Motor Learning

Full metadata record
DC Field Value Language
dc.contributor.authorJiang, Bing-
dc.contributor.authorKim, Jeonghee-
dc.contributor.authorPark, Hangue-
dc.date.accessioned2023-07-24T09:22:03Z-
dc.date.available2023-07-24T09:22:03Z-
dc.date.created2023-07-21-
dc.date.issued2022-03-
dc.identifier.issn1534-4320-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/187301-
dc.description.abstractIncomplete tongue motor control is a common yet challenging issue among individuals with neurotraumas and neurological disorders. In development of the training protocols, multiple sensory modalities including visual, auditory, and tactile feedback have been employed. However, the effectiveness of each sensory modality in tongue motor learning is still in question. The objective of this study was to test the effectiveness of visual and electrotactile assistance on tongue motor learning, respectively. Eight healthy subjects performed the tongue pointing task, in which they were visually instructed to touch the target on the palate by their tongue tip as accurately as possible. Each subject wore a custom-made dental retainer with 12 electrodes distributed over the palatal area. For visual training, 3 x 4 LED array on the computer screen, corresponding to the electrode layout, was turned on with different colors according to the tongue contact. For electrotactile training, electrical stimulation was applied to the tongue with frequencies depending on the distance between the tongue contact and the target, along with a small protrusion on the retainer as an indicator of the target. One baseline session, one training session, and three post-training sessions were conducted over four-day duration. Experimental result showed that the error was decreased after both visual and electrotactile trainings, from 3.56 +/- 0.11 (Mean I STE) to 1.27 +/- 0.16, and from 3.97 +/- 0.11 to 0.53 +/- 0.19, respectively. The result also showed that electrotactile training leads to stronger retention than visual training, as the improvement was retained as 62.68 +/- 1.81% after electrotactile training and 36.59 +/- 2.24% after visual training, at 3-day post training.-
dc.language영어-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titlePalatal Electrotactile Display Outperforms Visual Display in Tongue Motor Learning-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Jeonghee-
dc.identifier.doi10.1109/TNSRE.2022.3156398-
dc.identifier.scopusid2-s2.0-85125749480-
dc.identifier.wosid000767839400005-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, v.30, pp.529 - 539-
dc.relation.isPartOfIEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING-
dc.citation.titleIEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING-
dc.citation.volume30-
dc.citation.startPage529-
dc.citation.endPage539-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaRehabilitation-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryRehabilitation-
dc.subject.keywordPlusSPEECH-
dc.subject.keywordPlusELECTROPALATOGRAPHY-
dc.subject.keywordPlusFEEDBACK-
dc.subject.keywordPlusULTRASOUND-
dc.subject.keywordPlusMOVEMENTS-
dc.subject.keywordPlusTASKS-
dc.subject.keywordAuthorElectrotactile feedback-
dc.subject.keywordAuthormotor learning-
dc.subject.keywordAuthortongue-
dc.subject.keywordAuthorelectrical stimulation-
dc.subject.keywordAuthorintraoral device-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/9729199-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jeonghee photo

Kim, Jeonghee
COLLEGE OF ENGINEERING (SCHOOL OF ELECTRONIC ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE