Theoretical analysis on active radiant heat reflector integrated phase change material wall
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Gyu-Bae | - |
dc.contributor.author | Cheon, Seong-young | - |
dc.contributor.author | Kang, Yong-Kwon | - |
dc.contributor.author | Kim, Beom-Jun | - |
dc.contributor.author | Joung, Jae-Won | - |
dc.contributor.author | Jeong, Jae Weon | - |
dc.date.accessioned | 2023-08-01T06:40:41Z | - |
dc.date.available | 2023-08-01T06:40:41Z | - |
dc.date.created | 2023-07-21 | - |
dc.date.issued | 2022-05 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/188442 | - |
dc.description.abstract | Recently, as interest in increasing energy efficiency of buildings increases, a method of reducin g indoo r hea t gain and los s b y integrating phas e change material s (PCM ) into building wal ls is bein g studie d. Th e PC M is a typ e of he at storag e materi al th at ca n redu ce energy consumption o f the cooling and heating devices o f the building by absorbing o r releasing heat from outside . However , th e PCM which i s integrate d int o th e wal l o f th e buildin g canno t fully achieve thermal performance because it absorbs or releases heat according to the temperature change of the surrounding members in the wall. To solve the problem, this study proposed a new system that improves the thermal performance of the PCM integrated wall by controlling radiant heat transfer inside of the wall. The proposed system adjusts the radiant heat transfer in the wall through a n activ e radian t hea t reflecto r, which control s surface emissivit y o f th e PC M i n the design conditions. To evaluate the proposed system, a numerical analysis for 1D transient heat transfer was used based on the energy balance equation for the indoor heat gain and loss with the reference systems. The simulation was conducted with Matlab 2021a software, and weather conditions were data from the summer (Jun-August) and winter (December-February) of IWEC2 Seoul. As a result of the simulation, the proposed system confirmed that indoor heat gains and losse s wer e improve d i n al l period s compare d t o th e reference system . Th e propose d system reduced the total indoor heat gain by 33.3%-44.1% in summer and the total indoor heat loss by 14.2-29.3 in winter compared to the reference systems. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | REHVA | - |
dc.title | Theoretical analysis on active radiant heat reflector integrated phase change material wall | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Jeong, Jae Weon | - |
dc.identifier.doi | 10.34641/clima.2022.107 | - |
dc.identifier.bibliographicCitation | CLIMA 2022 Proceedings, pp.1 - 7 | - |
dc.relation.isPartOf | CLIMA 2022 Proceedings | - |
dc.citation.title | CLIMA 2022 Proceedings | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 7 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | PCM integrated wall | - |
dc.subject.keywordAuthor | Thermal performance | - |
dc.subject.keywordAuthor | Radiant heat transfer | - |
dc.identifier.url | https://proceedings.open.tudelft.nl/clima2022/article/view/107 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.